Stability Analysis of Circular Steel Dome Trusses Under Thermo‐Mechanical Loading From Localized Fire
Van Dat Pham, Ngoc Tien Dao
Key points
From the paper's conclusion- Three numerical examples are conducted, including validation under uniform temperature and analysis of two dome trusses (168 and 120 members) under five localized fire scenarios with a heat release rate of 5 MW.
Abstract
This paper presents a nonlinear stability analysis method for circular steel dome trusses subjected to localized fire. The method accounts for combined mechanical loads and thermal effects. The approach employs the Zukoski plume model for temperature distribution, an updated Lagrangian (UL) finite element formulation, and the displacement control (DC) method, while incorporating temperature‐dependent steel degradation according to Eurocode 3 (EC3). Two material models are examined: elastic (EL) and bilinear elastoplastic (EP). Three numerical examples are conducted, including validation under uniform temperature and analysis of two dome trusses (168 and 120 members) under five localized fire scenarios with a heat release rate of 5 MW. Based on the proposed method, a MATLAB code was developed to perform the numerical examples. Results indicate that (1) the EP model consistently yields lower critical loads than EL; (2) fires at or near the dome apex can induce thermal arching, increasing critical load; (3) for the two dome truss configurations investigated (168 and 120 members, S275 steel, ), the fire scenario at r Q = R /2 (FS3) is identified as the most hazardous, consistently yielding the lowest critical load; and (4) the second most hazardous scenario depends on the specific truss configuration, highlighting the need for case‐specific parametric studies. The proposed method effectively traces complete equilibrium paths and provides a parametric framework for preliminary stability assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Nonlinear buckling and post-buckling response of steel trusses under localized fire exposureAdvances in Science and Technology – Research Journal · 2026
- NUMERICAL ANALYSIS OF COLLAPSE BEHAVIOR OF STEEL FLOOR STRUCTURES IN FIRE CONSIDERING FIRE COMPARTMENT LOCATION AND TEMPERATURE OF PRIMARY BEAMSJournal of Structural and Construction Engineering (Transactions of AIJ) · 2026
- Fire-Induced Thermo-Mechanical Response, Damage Evolution, and Failure Mechanisms of Reinforced Concrete Structural SystemsEngineering Research Express · 2026
- On the role of the lantern in the safety of masonry domes: the case of Nuestra Señora de los Ángeles (Mexico City)Meccanica · 2026
- Compressive Capacity of Postfire Laser-Welded Stainless Steel I-Sections: Testing, Modeling, and DesignJournal of Structural Engineering · 2026
- Numerical Study on Seismic Behavior of Prefabricated Shear Wall with Sleeve Grouting Connection After FireBuildings · 2026