Applied bionics and biomechanics

Sports Technique Action Detection Method Based on Compressed Sequences and Multihead Cross Attention.

Xuelin Yang, Xiang Wu

International Ocean Sports College School of Physical Education Beibu Gulf University Qinzhou 535011 China en.bbgu.edu.cn. · School of Statistics and Data Science SWUFE Southwestern University of Finance and Economics Chengdu 611130 China swufe.edu.cn.

Key points

From the paper's conclusion
  • In view of the problems that traditional motion detection methods are susceptible to interference and have low stability, this study proposes a motion detection model using compressed sequence and multihead cross‐attention to monitor sports technical movements.

Abstract

Sports technical motion detection can analyze and evaluate the movements of athletes and is widely used in the field of sports competition. In view of the problems that traditional motion detection methods are susceptible to interference and have low stability, this study proposes a motion detection model using compressed sequence and multihead cross-attention to monitor sports technical movements. The study compresses the input data through a wavelet transform compression algorithm based on low-frequency subband transform and combines multihead attention (MHA) with cross attention to improve the motion detection network. The experimental results indicate that, in the evaluation and comparison of image quality after compression processing on the UVG and HEVC B datasets, the average peak signal-to-noise ratio (PSNR) of the wavelet transform compression algorithm based on low-band-shift (LBS) is 38.76 and 36.21, respectively. In the test experiment conducted on the THUMOS14 dataset, the average accuracy of the action detection model proposed in the study was 0.81, with a confidence interval of [0.78, 0.84]. In the test experiment on the annotated SoccerNetV2 dataset, the research method achieves a percentage of correct keypoints (PCKs) of 0.96 for head keypoints and 0.77 for ankle keypoints, with an average frame rate of 14 fps, demonstrating superior operational efficiency and accuracy. The confidence interval for the PCKs in the head at the 95% confidence level is [0.94, 0.98], and the confidence interval for the PCKs in the ankle at the same confidence level is [0.73, 0.81]. To summarize, the model presented in the study demonstrated better performance than the comparison models in terms of motion detection accuracy, stability, and running rate; has good prediction performance; and provides a more efficient application solution for the analysis and detection of sports technical movements.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers