Conventional transcutaneous spinal stimulation waveforms recruit sensory pathways more effectively than burst-modulated high-frequency waveforms.
Janie Provencher, Harrison T Finn, Simon C Gandevia, Jane Butler, Martin E Héroux
Spinal Cord Injury Research Centre, Neuroscience Research Australia, Randwick, NSW, Australia.
Key points
From the paper's conclusion- Overall, burst-modulated high-frequency waveforms required higher stimulation intensities than conventional waveforms to evoke spinally-evoked motor responses and provided no physiological evidence of an advantage over conventional waveforms.
Abstract
Transcutaneous spinal stimulation (TSS) can improve motor function in people with paresis, although outcomes remain inconsistent across studies. Different stimulation parameters may influence the effectiveness and sensory fiber selectivity of TSS. Here, we systematically compared the ability of ten TSS waveforms applied over the T11-L1 vertebral levels to evoke a soleus muscle response in people with intact neurological function (n = 12). Burst-modulated high-frequency waveforms (2 kHz, 5 kHz, 10 kHz) were compared with a conventional square waveform of the same total cathodal phase duration (400 μ s); a longer conventional waveform (1,000 μ s) was also tested. All waveforms were delivered in biphasic and monophasic pulse types. Relative to the conventional 400 μ s waveform, response threshold intensities were lower with the 1,000 μ s waveform (-28 to -27%) and higher with high-frequency stimulation: 2 kHz (+26 to +43%), 5 kHz (+111 to +129%), and 10 kHz (+254 to +273%). Recruitment curve slopes were also steeper with the 1,000 μ s waveform (+33 to +46%) and generally less steep with high-frequency stimulation: 2 kHz (biphasic: -25%), 5 kHz (-50 to -46%), and 10 kHz (-75 to -64%). Paired-pulse depression was weak at intensities >100%-120% of threshold but increased markedly at higher intensities across all waveforms. The 10 kHz waveforms showed the weakest paired-pulse depression, consistent with a smaller sensory contribution than the conventional 400 μ s waveform. Onset latencies were comparable to peripheral conduction times at near-threshold intensities but became shorter at higher stimulation intensities, suggesting changes in the relative contributions of sensory and motor fiber activation. Overall, burst-modulated high-frequency waveforms required higher stimulation intensities than conventional waveforms to evoke spinally-evoked motor responses and provided no physiological evidence of an advantage over conventional waveforms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fundamental limitations of kilohertz-frequency carriers in afferent fibre recruitment with transcutaneous spinal cord stimulationNature Biomedical Engineering · 2026
- Delayed Reduction in Painful Sensations Evoked by Cervical tSCS Following High-Frequency StimulationbioRxiv · 2026
- Excitability of Posterior Root Reflex Evoked by Transcutaneous Spinal Stimulation is Distinct from H-reflex in the Soleus Muscle: A Pulse Duration Study.Journal of neurophysiology · 2026
- Real-world use of transcutaneous spinal neuromodulation combined with activity-based rehabilitation across neurological disorders: a retrospective post-market study.Frontiers in medical technology · 2026
- Neural mechanisms underlying leg muscle responses during cervical transcutaneous spinal cord stimulationJournal of Neural Engineering · 2026
- A method of compensating for the excitability of spinal motoneurones when estimating the magnitude of potentials evoked in skeletal musclesThe Journal of Physiology · 2026