Journal of applied physiology (Bethesda, Md. : 1985)

Comparison of 5% fixed-concentration CO2 inhalation and PETCO2 clamping for assessing cerebrovascular endothelial function: the role of shear rate normalization.

Erika Iwamoto, Koki Akanuma, Arata Tsunekawa, Tatsuki Kamoda, Rintaro Sakamoto, Saki Yamamoto, Toru Neki, Masaki Katayose,

School of Health Sciences, Sapporo Medical University, Sapporo, Japan. · Graduate School of Health Sciences, Sapporo Medical University, Sapporo, Japan.

Review

Key points

From the paper's conclusion
  • These findings suggest that inhalation of 5% fixed-concentration CO2 can provide ICA-FMD responses comparable to those of PETCO2 clamping when differences in the shear stimulus are accounted for.

Abstract

Although internal carotid artery flow-mediated dilation (ICA-FMD) is a promising noninvasive measure of cerebrovascular endothelial function, its wider application has been limited by the technically demanding end-tidal CO₂ partial pressure (PETCO2) clamp technique. We investigated whether a simplified fixed-concentration CO2 inhalation method provides ICA-FMD measurements comparable to the PETCO2 clamping method and whether shear rate (SR) normalization improves agreement between the two methods. Eighteen healthy young adults underwent ICA-FMD assessment using two 30-s hypercapnic stimuli: PETCO2 clamp (target ΔPETCO2 +9 mmHg) and fixed-concentration CO₂ inhalation (5% CO2 gas), in a randomized crossover design. ICA-FMD, SR area under the curve (SRAUC), and SRAUC above baseline (DSRAUC) were determined. ΔPETCO2 and ICA-FMD were lower during fixed-concentration CO2 inhalation than during the PETCO2 clamp method (6.9 ± 1.3 vs. 9.4 ± 1.5 mmHg and 3.5 ± 1.5 vs. 4.5 ± 2.1%, respectively; P < 0.05 for both). Normalization of ICA-FMD to SRAUC and DSRAUC eliminated the between-method differences (P > 0.05 for both). Repeated-measures correlation revealed a within-subject association between ICA-FMD and DSRAUC (rrm = 0.61, P < 0.01), but not SRAUC (rrm = 0.32, P = 0.19). Bland-Altman analysis showed that normalization to DSRAUC improved agreement between methods, increasing the intraclass correlation coefficient from 0.44 (95% CI, -0.02 to 0.75) for unnormalized ICA-FMD to 0.81 (95% CI, 0.57 to 0.93) for ICA-FMD/DSRAUC. These findings suggest that inhalation of 5% fixed-concentration CO2 can provide ICA-FMD responses comparable to those of PETCO2 clamping when differences in the shear stimulus are accounted for.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers