ARNAI: Artifact Removal Network Based on Autoencoding and Inpainting for Robust Spinal Image Segmentation and Measurement
Sang-Jin Park, Jinyoung Choi, Seokwon Kim, Seungeon Song, Insu Park, Dougho Park, Taeyeon Kim, Youjin Lee,
Pohang TechnoPark (South Korea) · Handong Global University
Key points
From the paper's conclusion- The Restore, Segment, and Measure (RSM) framework was developed, incorporating a novel Artifact Removal Network based on Autoencoding and Inpainting (ARNAI) to mitigate implant-related artifacts.
Abstract
Purpose To develop an artificial intelligence framework, robust to spinal implants, for automated measurement of spinopelvic parameters on postoperative radiographs. Materials and Methods Lateral lumbar spine radiographs from two institutions (internal dataset [ n = 2486]: January 2017-December 2024; external dataset [ n = 217]: October 2021-September 2025) were retrospectively reviewed. The Restore, Segment, and Measure (RSM) framework was developed, incorporating a novel Artifact Removal Network based on Autoencoding and Inpainting (ARNAI) to mitigate implant-related artifacts. Segmentation and spinopelvic parameter (including segmental Cobb angle [SCA]) measurement performance relative to expert reference measurements were assessed using the Dice similarity coefficient (DSC), mean absolute error (MAE), Wilcoxon signed-rank tests, and Benjamini-Hochberg correction for multiple comparisons. Results With ARNAI added to the segmentation pipeline, the mean DSC increased to 0.870 from 0.814, with marked gains at L3-L5. For implant-containing radiographs in the internal test set, rejected radiographs decreased by 64.21% (95 to 34), and the L4-L5 SCA MAE decreased to 4.7° from 16.2°-15.6° (~ 70% reduction); this remained significant after correction. For the external test set, rejected radiographs decreased by 65.45% (110 to 38), and the L4-L5 SCA MAE decreased to 9.5°-9.7° from 14.2°-14.5° (~ 33% reduction); however, this improvement did not remain significant after correction, and agreement with expert references remained limited. Conclusion The RSM framework improved automated spinopelvic parameter measurement in implant-containing postoperative radiographs, with the greatest benefit observed for L4-L5 SCA estimation in the internal dataset. In the external dataset, error was reduced but agreement remained limited. © RSNA, 2026
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence Versus Manual Measurement of Spinopelvic Sagittal Parameters Across Preoperative, Postoperative, and Instrumented Spines: A Systematic Review of Diagnostic Accuracy, Failure Rates, and Inferred Surgical Planning Implications.Cureus · 2026
- Fully Automated Deep Learning-Based Lenke Classification for Adolescent Idiopathic Scoliosis Using Multi-View Full-Spine Radiographs: Development and Clinical Validation.Global spine journal · 2026
- Automatic Vertebral Body Segmentation Performance in Lateral Thoracic Spine X-Rays: A Comparative Analysis Based on Implant Presence and Subtype.Journal of imaging informatics in medicine · 2026
- AI-driven Assessment of Vertebral Rotation in Adolescent Idiopathic Scoliosis Using Weight-bearing Cone-beam CT.Academic radiology · 2026
- Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow IntegrationarXiv · 2026
- Accurate Cobb Angle Estimation via SVD-Based Curve Detection and Vertebral Wedging QuantificationIEEE Journal of Biomedical and Health Informatics · 2025