Probing millicharged particles with NA64$$\mu $$ and LDMX
Sergei N. Gninenko, N. V. Krasnikov, Sergey Kuleshov, Valery E. Lyubovitskij, P. Crivelli, D. V. Kirpichnikov, L. Molina Bueno, Alexey S. Zhevlakov,
Millennium Institute · Universidad Andrés Bello
Key points
From the paper's conclusion- Our results demonstrate that LDMX can probe heavier MCPs in the mass range $$250~\text{ MeV } \lesssim m_\chi \lesssim 400 ~\text{ MeV }$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>250</mml:mn> <mml:mspace/> <mml:mspace/> <mml:mtext>MeV</mml:mtext> <mml:mspace/> <mml:mo>≲</mml:mo> <mml:msub> <mml:mi>m</mml:mi> <mml:mi>χ</mml:mi> </mml:msub> <mml:mo>≲</mml:mo> <mm
Abstract
Abstract Millicharged particles emerge as compelling candidates in numerous theoretically well-motivated extensions of the Standard Model. These hypothetical particles, characterized by an electric charge that is a small fraction of the elementary charge, have attracted significant attention in contemporary experimental physics. Their potential existence motivates dedicated search strategies across multiple experimental platforms, leveraging their distinctive electromagnetic interactions while evading conventional detection methods. In the present paper we estimated the projected sensitivity of fixed-target experiments, specifically NA64 $$\mu $$ μ and LDMX, to the parameter space of millicharged particles. For the NA64 $$\mu $$ μ experiment, with an anticipated muon flux of $$\text{ MOT }\lesssim 10^{14}$$ MOT ≲ 10 14 , our analysis reveals a detectable mass window of $$10~\text{ MeV } \lesssim m_\chi \lesssim 150~\text{ MeV }$$ 10 MeV ≲ m χ ≲ 150 MeV and charge parameter range $$10^{-4} \lesssim \epsilon \lesssim 7\times 10^{-4}$$ 10 - 4 ≲ ϵ ≲ 7 × 10 - 4 . This sensitivity arises from the bremsstrahlung-like missing energy signature $$\mu N \rightarrow \mu N \gamma ^{*}( \rightarrow \chi \bar{\chi })$$ μ N → μ N γ ∗ ( → χ χ ¯ ) . Furthermore, we evaluate the discovery potential of the LDMX facility, considering its projected electron beam statistics, $$\text{ EOT }\lesssim 2\times 10^{16}$$ EOT ≲ 2 × 10 16 , and energy, $$E_\textrm{e}\simeq 8~\text{ GeV }$$ E e ≃ 8 GeV . Our results demonstrate that LDMX can probe heavier MCPs in the mass range $$250~\text{ MeV } \lesssim m_\chi \lesssim 400 ~\text{ MeV }$$ 250 MeV ≲ m χ ≲ 400 <mml:mspace/
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Underground production of electromagnetic dark states by MeV-scale electron beams and detection with CCDsJournal of High Energy Physics · 2026
- MoEDAL-MAPP: the first dedicated search experiment at the LHCarXiv · 2026
- Resonant Cavity Searches for Millicharged Dark MatterarXiv · 2026
- Millicharged Fermions as Dark Matter: Theoretical Modeling and Experimental DetectionarXiv · 2026
- Electric accumulation of millicharged particlesPhysical review. D/Physical review. D. · 2026