Comparison of endothelin-1 levels in human plasma from human coronary arteries measured by enzyme linked immunosorbent assay and Olink high-throughput proteomics platform.
Majid Anwar, Rhoda E Kuc, Catherine Bullock, George R Abraham, Janet Maguire, Stephen P Hoole, Diane Proudfoot, Anthony P Davenport
University of Cambridge, Experimental Medicine and Immunotherapeutics, Cambridge, United Kingdom of Great Britain and Northern Ireland. · University of Cambridge, Experimental Medicine and Immunotherapeutics, Cambridge, England, United Kingdom of Great Britain and Northern Ireland; rek22@medschl.cam.ac.uk.
Key points
From the paper's conclusion- These findings indicate that the Olink Explore platform can detect relative changes in biologically active ET-1, supporting its use as a biomarker tool in clinical and translational studies.
Abstract
Endothelin-1 (ET-1) antagonists are increasingly being approved for new treatments for cardiovascular disease, where elevated ET-1 levels contribute to increased vasoconstriction. Further therapeutic targets, including coronary artery disease, are under investigation. The Olink Explore 3072 Proximity Extension Assay platform enables multiplexed high throughput measurement of ~3000 plasma proteins, from minimal (≤6µl) sample volumes. However, it is not known if the two oligonucleotide‑tagged antibodies raised against preproET-1₁-₂₁₂, used in this Olink assay, specifically measure biologically active ET-1 or the other inactive EDN1-encoded peptides, also secreted by human endothelial cells. Paired plasma samples from 29 patients with coronary artery disease were obtained, using a specialised intra-coronary sampling catheter, designed to obtain site specific biochemical information from within coronary arteries. We compared ET-1 concentrations measured with an ET-1 specific ELISA, demonstrated to have no cross reactivity with other EDN1-encoded peptides versus values obtained using Olink Explore platform. Olink-measured ET-1 correlated significantly with ELISA-derived ET-1 levels (r=0.53, p=0.003), and Olink values predicted ELISA results. Olink ET-1 concentrations also correlated with ETB receptor levels (r=0.40, p< 0.05). These findings indicate that the Olink Explore platform can detect relative changes in biologically active ET-1, supporting its use as a biomarker tool in clinical and translational studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Current approaches and future directions of Endothelin-1 detection.Clinica chimica acta; international journal of clinical chemistry · 2026
- Circulating Endothelin-2 and Endothelin-3 as Potential Non-Invasive Biomarkers of Carotid Plaque Instability in Patients Undergoing Carotid Endarterectomy.Medical sciences (Basel, Switzerland) · 2026
- The unexplainable plasma protein measurements from Proximity Extension AssaysmedRxiv · 2026
- High Lipoprotein(a) levels and coronary plaque burden: 175 nmol/L as a potential target for early CT-based risk assessmentEuropean Heart Journal · 2026
- Assay-Dependent Variability in RBP4 and Adiponectin Quantification Affects Associations with Coronary Disease Severity and Doppler Echocardiographic Indices: A Comparative Study of Immunoturbidimetry and ELISA.International journal of general medicine · 2026
- Profiles of Third-Trimester Maternal Vascular Marker Endothelins in Circulation by HPLC-Fluorescence Method and Relationships Among the Vasoactive Markers in the Maternal-Infant Research on Environmental Chemicals (MIREC) Study.Biomedicines · 2026