When gastric point-of-care ultrasound changes management: a research letter.
Stephen C Haskins, Yuriy Bronshteyn, Cristian Arzola, Hari Kalagara, David Hardman, Oliver Panzer, Marissa M Weber, Eric Heinz,
Department of Anesthesiology, Critical Care & Pain Management, Hospital for Special Surgery, New York, New York, USA haskinss@hss.edu. · Department of Anesthesiology, Duke University Medical Center, Durham, North Carolina, USA.
Key points
From the paper's conclusion- We performed a focused secondary analysis of 65 studies from the study-level extraction associated with a previously published ASRA Pain Medicine narrative review to determine how often gastric POCUS studies evaluated or reported changes in management.
Abstract
Gastric point-of-care ultrasound (POCUS) is increasingly used to assess aspiration risk, but studies differ in whether ultrasound is used to validate the technique, characterize gastric contents in populations, or guide bedside clinical decisions. We performed a focused secondary analysis of 65 studies from the study-level extraction associated with a previously published ASRA Pain Medicine narrative review to determine how often gastric POCUS studies evaluated or reported changes in management. Studies were categorized by primary study purpose as foundational/validation/diagnostic-performance/reliability, clinical POCUS/decision-impact, or population/intervention research. Of 65 studies, 2 were clinical POCUS/decision-impact studies, 9 were foundational/validation studies, and 54 were population/intervention studies. Management-change status was reported or extractable in 8 studies and prespecified in 3; all 8 reported at least one actual management change, with rates ranging from 0.4% to 46%. Both clinical POCUS studies prespecified a management change, with reported change rates of 5.0% and 18.9%, respectively. Reported changes included rapid sequence induction, airway modification, postponement or cancellation, conversion to local/regional anesthesia, and more liberal or conservative aspiration-risk management. No study clearly linked management change to patient-centered outcomes. Future clinical gastric POCUS studies should prospectively define the indication, pre-scan plan, scan findings and decision thresholds, post-scan decision, and reason for change or non-change, while evaluating downstream patient-centered outcomes, resource utilization, and potential harms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- When gastric point-of-care ultrasound is indeterminate: an educational review and suggested reporting framework.Regional anesthesia and pain medicine · 2026
- Clinical applications of gastric point-of-care ultrasound in adult emergency and critical care: a scoping review.CJEM · 2026
- Feasibility of gastric point-of-care ultrasound (G-POCUS) to determine gastric content after gastrointestinal surgery: A prospective pilot study.Surgery · 2026
- Benefits of Point-of-Care Ultrasound for Assessing Gastric Contents.Ochsner journal · 2026
- Gastrointestinal point-of-care ultrasound for enteral nutrition management in critically ill adults: a scoping review.Frontiers in nutrition · 2026
- Clinical roles of point-of-care ultrasonography in airway managementAnesthesia and Pain Medicine · 2025