Maintaining quality out-of-hours in an acute cardiology service in a UK primary PCI centre.
Cullum Shaw, Karen Roberts, Karen McDonagh, Adam Frosdick, Melody Thomas, Faye Robson, Lissy Jose, Kerry Moore,
Kettering General Hospital, Kettering, UK. · Kettering General Hospital, Kettering, UK ayman.helal1@nhs.net.
Key points
From the paper's conclusion- COPs demonstrated a high level of exact diagnostic concordance when compared with discharge diagnosis made by consultant cardiologist. This new evidence suggests that COP-led assessments are reliable when working within a clinical pathway.
Abstract
BACKGROUND: Many district general hospitals (DGHs) in the UK do not have resident on-call cardiology registrars overnight; in these situations, it is becoming more common for cardiac outreach practitioners (COPs) to provide specialist input for patients presenting with suspected cardiac events. The aim of this study is to evaluate the exact diagnostic concordance between the initial working diagnoses made independently by COPs and subsequent final discharge diagnoses in patients assessed out of hours and to assess the accuracy of identifying acute coronary syndrome (ACS). METHODS: A retrospective, single-centre service evaluation was conducted at a UK DGH between January and June 2025. Initial COP diagnoses were compared with final discharge diagnoses, with exact diagnostic concordance reported as percentage agreement. Diagnostic performance for identifying ACS was assessed using sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy and Cohen's kappa (κ). RESULTS: A total of 779 cases were screened, with 233 patients meeting inclusion criteria following staged exclusions. The overall exact diagnostic concordance was 92.7% (216/233). The 216 exact concordant cases comprised 125 concordant cardiac diagnoses and 91 concordant non-cardiac diagnoses. 17 cases had discordant diagnoses, but none were associated with delayed escalation, investigation or management. COP sensitivity for identifying ACS was 96.0%, specificity was 92.4%, positive predictive value was 85.9%, negative predictive value was 98.0% and overall classification accuracy was 93.6%. Cohen's κ was 0.858 (95% CI 0.789 to 0.927), indicating almost-perfect agreement. CONCLUSION: COPs demonstrated a high level of exact diagnostic concordance when compared with discharge diagnosis made by consultant cardiologist. This new evidence suggests that COP-led assessments are reliable when working within a clinical pathway.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement between fully automated artificial intelligence and cardiac radiologists for coronary stenosis and plaque assessment in an asymptomatic screening cohort.The international journal of cardiovascular imaging · 2026
- Safety and efficiency of the HEART-GP strategy with point-of-care high-sensitivity troponin testing for acute chest pain in out-of-hours primary care: a prospective multicentre diagnostic accuracy studymedRxiv · 2026
- Clinical triage concordance of a point-of-care high-sensitivity cardiac troponin I assay using the ESC 0/1-hour algorithm.Clinica chimica acta; international journal of clinical chemistry · 2026
- Real-World Validation of the AI-Enabled Vectorcardiographic CSG-Index for Obstructive Coronary Artery Disease: The VECTOR-CAD Study.Diagnostics (Basel, Switzerland) · 2026
- Artificial intelligence-assisted ECG interpretation for identification of occlusive myocardial infarction following cardiac arrest: a multi-reader, multi-case studyScientific Reports · 2026
- Availability-Aware Prediction of CCTA Findings Using Opportunistic Low-Dose CT and Routine Health-Check Data.Journal of imaging informatics in medicine · 2026