科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Heart (British Cardiac Society)2026-08-07

Association of incomplete device apposition with stroke recurrence after patent foramen ovale closure.

Chaowu Yan, Hua Li, Linyuan Wan, Ang Liu, Pingcuo Yundan, Cheng Wang, Yuhua Zhao, Lei Wang, Wei Fang

一句话结论 · In one sentence

IDA is common after PFO closure and is associated with increased risks of recurrent stroke and new-onset symptoms. Preventive strategies warrant further investigation.

原始摘要(英文原文)· Original abstract
BACKGROUND: The mechanisms underlying stroke recurrence after patent foramen ovale (PFO) closure for secondary prevention remain poorly understood. This study evaluated incomplete device apposition (IDA) using cardiac CT angiography (CTA) and investigated its association with stroke recurrence. METHODS: In this prospective cohort study conducted at four centres in China (2020-2026), 233 patients (mean age: 37.01±6.73 years; 48.9% male) without known vascular risk factors were included from 382 consecutive candidates who underwent transcatheter PFO closure with follow-up ≥6 months. Cardiac CTA at 6 months post closure assessed the presence, location and extent of IDA defined as a gap between the left disc and the interatrial septum. Recurrent stroke and new-onset symptoms (atrial tachyarrhythmia, migraine headache, chest pain/discomfort) were recorded and their associations with IDA were analysed. RESULTS: IDA was observed in 55.8% of patients predominantly at the anterior-inferior rim (93.4%). IDA was significantly associated with larger and longer PFOs, larger devices and greater in vivo device thickness (p < 0.001 for all). During a median follow-up of 20.00 (IQR 18.00-24.00) months, patients with IDA had a higher risk of recurrent stroke (log-rank p = 0.022) and new-onset symptoms (log-rank p < 0.001). In eight patients who underwent repeat CTA, device apposition remained stable after 6-month closure. Pathological validation was available in one patient with severe chest pain/discomfort and a well-apposed device had sufficient endothelialisation. CONCLUSION: IDA is common after PFO closure and is associated with increased risks of recurrent stroke and new-onset symptoms. Preventive strategies warrant further investigation. TRIAL REGISTRATION NUMBER: NCT04686253.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Association of incomplete device apposition with stroke recurrence after patent foramen ovale closure. — 科研速览 Science Skim