Octyl-butyl cyanoacrylate glue versus splint for stabilising short peripheral intravenous catheters in neonates: a retrospective cohort study.
Matheus Fpt van Rens, Kevin Hugill, Robin van der Lee, Airene Lv Francia, Fredericus Hj van Loon, Mohammad Aa Bayoumi
Neonatal Intensive Care Unit, Amalia Children's Hospital, Radboud University Medical Center, Nijmegen, Netherlands. · Department of Nursing and Midwifery Education, Hamad Medical Corporation, Doha, Qatar.
Key points
From the paper's conclusion- Cyanoacrylate glue represents a safe and effective strategy for stabilising SPCs in neonates. Glue-based securement is associated with a substantially lower incidence of phlebitis and, when combined with splinting, may further reduce the risk of dislodgement. These findings support the integration of adhesive-based securement into neonatal vascular access practice.
Abstract
AIM: This study was conducted to compare the effectiveness of octyl-butyl cyanoacrylate glue or limb splinting used alone or in combination for stabilising neonatal short intravenous peripheral catheters (SPCs). MATERIALS AND METHODS: This retrospective cohort study analysed routinely collected data from a tertiary neonatal intensive care unit. A total of 45 754 successfully inserted SPCs were grouped into one of three stabilisation strategies: splint+glue, splint only and glue alone. The primary outcome was SPC dislodgement. Secondary outcomes included dwell time, phlebitis, infiltration and extravasation. Multivariable logistic regression analysis was performed to adjust for potential confounders. RESULTS: Of the included SPCs, 1404 were stabilised using splint+glue, 12 006 using splint only and 32 344 using glue alone. In the unadjusted analysis, dislodgement differed between the groups (splint+glue, 1.5%; splint, 2.2%; glue, 2.6%; p=0.002). The median dwell time was the longest in the glue group (33.8 hours), although differences were not clinically significant. The incidence of phlebitis was the highest in the splint group (13.4%) compared with those in the glue (3.8%) and splint+glue (4.2%) groups (p<0.001). Kaplan-Meier survival analysis revealed statistically significant differences between the groups (p<0.001), with the splint+glue group exhibiting the highest catheter survival and the splint group the lowest. In multivariable analysis, the combined use of splint and glue was independently associated with reduced odds of dislodgement. Glue-based securement strategies were also associated with significantly lower odds of phlebitis compared with splint-only stabilisation. CONCLUSION: Cyanoacrylate glue represents a safe and effective strategy for stabilising SPCs in neonates. Glue-based securement is associated with a substantially lower incidence of phlebitis and, when combined with splinting, may further reduce the risk of dislodgement. These findings support the integration of adhesive-based securement into neonatal vascular access practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of two securement methods on peripherally inserted central catheter stability and skin integrity in very low birth weight infants: a retrospective study.Translational pediatrics · 2026
- Peripheral intravenous catheter fixation splint in pediatrics, FIX I/V: A proof-of-concept study protocolmedRxiv · 2026
- Liposomal bupivacaine utilization in the pain management of postoperative selective dorsal rhizotomy patients.Journal of neurosurgery. Pediatrics · 2026
- The efficacy of needleless connector designs (split septum vs mechanical valve) on preventing central line-associated bloodstream infection (CLABSI) in very preterm or very low-birth-weight neonates: a randomized clinical trial.Infection control and hospital epidemiology · 2026
- Complications associated with the insertion site of arterial catheters in intensive care: A propensity score-matching analysis.Intensive & critical care nursing · 2026
- Peripheral IV Catheter Longevity With Ultrasound Guidance in the PICU: Single-Center Retrospective Cohort, 2016-2018.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2026