Diagnostic accuracy of the passive mast cell activation test in neuromuscular blocking agent-induced perioperative anaphylaxis in a tertiary hospital in China: a diagnostic accuracy study.
Zhe Li, Xiaowen Liu, Huamei Cai, Tao Zhang, Jing Zhao
Department of Anesthesiology, China-Japan Friendship Hospital, Beijing, China. · School of Pharmacy, Xi'an Jiaotong University, Xi'an, China taozhang@xjtu.edu.cn zhaojing1009@aliyun.com.
Key points
From the paper's conclusion- pMAT demonstrated high diagnostic accuracy for NMBA allergy, filling critical gaps in current POA diagnostic workflow. Its robust performance supports its clinical utility as a complementary tool alongside ST and BAT.
Abstract
OBJECTIVES: The passive mast cell activation test (pMAT) is a novel in vitro assay designed to complement existing tools like the skin test (ST) and basophil activation test (BAT) for allergen identification. This study aimed to validate the diagnostic accuracy of pMAT specifically for neuromuscular blocking agent (NMBA)-induced perioperative anaphylaxis (POA). DESIGN: A diagnostic accuracy study. SETTING: A tertiary hospital in Beijing, China. PARTICIPANTS: 44 patients with suspected POA were enrolled. Participants were stratified into groups based on ST and/or BAT. The NMBA-allergic group comprised 15 patients with confirmed NMBA allergy while the non-NMBA-allergic group consisted of 29 individuals without NMBA allergy. INTERVENTIONS: All participants underwent pMAT testing for relevant NMBA. PRIMARY AND SECONDARY OUTCOME MEASURES: The diagnostic performance of pMAT for NMBA was assessed by measuring sensitivity, specificity, likelihood ratios and the Youden index. An exploratory analysis evaluated its performance in diagnosing antibiotic-induced allergies within the same population. RESULTS: For NMBA allergy, pMAT demonstrated high diagnostic accuracy (90.9%; 95% CI 77.4% to 97.1%) with excellent sensitivity (93.3%; 95% CI 66.0% to 99.7%) and specificity (89.7%; 95% CI 71.5% to 97.3%). This was reflected in a high positive likelihood ratio (9.05; 95% CI 3.06 to 26.57), a low negative likelihood ratio (0.07; 95% CI 0.01 to 0.50), a Youden index of 0.83 and a Cohen's kappa of 0.804 (indicating substantial agreement with the reference standard). In contrast, pMAT showed reduced performance for antibiotic allergy, with an accuracy of 79.5% (95% CI 64.3% to 89.7%), sensitivity of 66.7% (95% CI 30.9% to 91.0%), specificity of 82.9% (95% CI 65.7% to 92.8%) and a kappa of 0.378 (fair agreement). CONCLUSIONS: pMAT demonstrated high diagnostic accuracy for NMBA allergy, filling critical gaps in current POA diagnostic workflow. Its robust performance supports its clinical utility as a complementary tool alongside ST and BAT. TRIAL REGISTRATION NUMBER: ChiCTR2400084268.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Perioperative Anaphylactic Shock Induced by Cisatracurium: A Case Demonstrating the Diagnostic and Clinical Value of Early Skin Testing.The American journal of case reports · 2026
- Under the Drapes: Unmasking the Mechanisms and Clinical Diagnosis of Perioperative Hypersensitivity.Current allergy and asthma reports · 2026
- Recurrent anaphylaxis highlighting methodological variability and diagnostic challenges in the basophil activation test: a case report.JA clinical reports · 2026
- Development of a Mast-Cell Activation Test for Diagnosing Allergic Rhinitis.Journal of immunology research · 2026
- Urine mast cell mediators and anaphylaxis.Current opinion in allergy and clinical immunology · 2026
- Safety of drug provocation testing and subsequent clinical use of local anesthetics in patients with suspected hypersensitivityFrontiers in Allergy · 2026