Prompt sensitivity affects large language model decision-making in aortic stenosis: a real-world study of severity classification, treatment recommendation and exploratory prognostic analysis.
Hai-Quan Huang, Shao-Hong Wu, Ying Ban, Cui-Ling Li, Rui Fan, Min Ye, Yan-Qiu Liu, Dong-Hong Liu,
Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China. · Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China liwei259@mail.sysu.edu.cn yaofj@mail.sysu.edu.cn.
Key points
From the paper's conclusion- LLMs require prompt standardisation, class-specific evaluation and prospective validation before clinical use.
Abstract
OBJECTIVES: Aortic stenosis (AS) assessment requires integration of discordant echocardiographic and clinical information. The reliability of large language models (LLMs) across prompts and AS phenotypes remains uncertain. This study aimed to compare five LLMs across four prompting strategies for AS severity classification, real-world intervention concordance and exploratory prognostic associations. METHODS: This retrospective study evaluated five LLMs across four prompting strategies in 1455 patients with AS. Task 1 assessed AS severity classification and Task 2 assessed real-world intervention concordance. Performance was summarised by accuracy, balanced accuracy and macro-F1. Exploratory associations of the best performing Task 2 configuration with all-cause mortality and heart failure progression were examined using Kaplan-Meier analysis and multivariable Cox regression. RESULTS: GPT-o1/chain-of-thought (CoT) achieved the highest Task 1 accuracy (97.53%), balanced accuracy (90.93%) and macro-F1 (83.19%). Grok-2/CoT achieved the highest Task 2 concordance (88.32%). Grok-2/CoT recommendations separated heart failure progression-free survival in unadjusted analysis (p=0.006) but not overall survival (p=0.105). After adjustment, recommendation group was not independently associated with mortality (HR 1.41, 95% CI 0.58 to 3.45, p=0.453) or heart failure progression (HR 1.10, 95% CI 0.44 to 2.74, p=0.832). DISCUSSION: LLM performance varied by model, task and prompt. Apparent prognostic separation observed in unadjusted analysis was not retained after adjustment for clinical characteristics, AS severity and actual intervention. CONCLUSION: LLMs require prompt standardisation, class-specific evaluation and prospective validation before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessing the Limitations of Large Language Models in Clinical Practice Guideline–Concordant Treatment Decision-Making on Real-World Data: Retrospective StudyJMIRx Med · 2025
- Evaluation of Small and Large Language Models for Calculation of the ASA Score and Charlson Comorbidity Index in Orthopedic Surgical Patients: A Retrospective Concordance Analysis.Bioengineering (Basel, Switzerland) · 2026
- Harnessing large language models for reliable automatic Charlson Comorbidity Index scoring: a validation study.JAMIA open · 2026
- Development and External Validation of an Echocardiography-Based AI Model for Predicting Aortic Stenosis Progression.JACC. Advances · 2026
- Evaluating the Performance of Large Language Models in Vascular Surgery Cases: Cross-Sectional Study.JMIR perioperative medicine · 2026
- Large Language Models (LLMs) vs Manual Chart Review for Assessing Goal-Concordant Care: An Exploratory Study.The American journal of hospice & palliative care · 2026