Quantitative Assessment of Se(p,xn) Routes to Medical Bromine Radioisotopes
Duaa Abed Salim, Rusul A. Najem, Bassam Thaban
Mustansiriyah University · Iraqi University
Key points
From the paper's conclusion- The results demonstrated that the 77Se(p,2n)76Br and 78Se(p,2n)77Br reactions are among the most significant production routes, yielding 224.4 and 284.1 mCi/(µA h), respectively, with radionuclidic purities of 96.8 and 85.5%.
Abstract
Abstract This study investigates proton-induced reactions on enriched selenium targets, focusing on the production of bromine radioisotopes, which are of significant medical relevance for both diagnostic imaging and therapeutic applications. The study employs Monte Carlo samples to evaluate for experimental uncertainty in energy and cross-section simulations, then enters corrected energy into TALYS 2.0 and compares corrected cross-sections to predictions. The relative variance technique was used for assessing experimental data from the EXFOR database using nuclear level density models that are included of the TALYS 2.0 code. The results demonstrated that the 77Se(p,2n)76Br and 78Se(p,2n)77Br reactions are among the most significant production routes, yielding 224.4 and 284.1 mCi/(µA h), respectively, with radionuclidic purities of 96.8 and 85.5%. The CTM and TGHFB models exhibited the lowest relative variance in both reactions, despite the SHFB being the best model in several of the reactions under study. According to our findings, the statistical analysis procedure is a practical tool that processes cross-section and energy ranges of nuclear reaction accuracy to reduce uncertainty in calculations, hence facilitating new applications in nuclear research and medicine.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimization of 99mTc proton-induced production by means of cross-section measurements of technetium radioisotopes from molybdenum targetsarXiv · 2026
- Nuclear Data Evaluation Utilizing Bayesian Monte Carlo MethodsarXiv · 2026
- Observation of $^{71}$Cr and expanded cross-section measurements and analysis of $^{82}$Se fragmentationarXiv · 2026
- Proton boron capture therapy and neutron capture enhanced proton therapy: a critical review of investigational approaches in proton therapy.Radiological physics and technology · 2026
- Assessment of the 49Ti(d,x) route to produce the theranostic radionuclide 47Sc based on cross-section measurements.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- A comprehensive microdosimetric study of neutron capture enhanced proton therapy: physical dose to RBE-based evaluation.Journal of radiation research · 2026