Analytical validation of a highly accurate and reliable next-generation sequencing-based urine assay
Mara Couto-Rodriguez, David Danko, Heather Wells, S. I. Rey, Xavier Jirau Serrano, Gábor Fidler, John C Papciak, Patrick Ford Combs,
BioScientia (Poland) · SUNY Downstate Health Sciences University
Key points
From the paper's conclusion- Overall, these data demonstrate that BIOTIA-ID is a highly accurate clinical-grade diagnostic tool with notable advantages over current culture- based diagnostics.
Abstract
ABSTRACT Culture is currently the gold standard for diagnosis of urinary tract infections (UTIs); however, it has poor sensitivity detecting urogenital pathogens, especially if patients have already initiated antimicrobial therapy, or have an infection from an organism that is not commonly cultured. False negative urine culture results can lead to the inappropriate use of antimicrobial therapies or to the progression to urosepsis in high-risk patients. Though not commonly applied to urine in a clinical setting, Next-generation sequencing (NGS)-based metagenomics offer a solution as a precision diagnostic. We developed and validated BIOTIA-ID, a clinical-grade NGS-based diagnostic pipeline for the detection and identification of pathogens in urine specimens. Remnant clinical urine specimens, and contrived sterile urine spiked with common UTI pathogens, were processed with our end-to-end assay including extraction, metagenomic library preparation and Illumina NextSeq 550 sequencing. We trained and applied a bioinformatic pipeline that uses machine learning (ML) to identify pathogens. Internal controls and other quality control measures were incorporated into the process to provide rigorous and standardized results. The assay was tested on 1,470 urine specimens and achieved 99.92% sensitivity, 99.95% specificity and a limit of detection (LoD) of <25,000 CFU/mL and <5,000 CFU/mL in bacteria and fungi, respectively. Discordant results were reconciled with additional testing by target-specific qPCR or 16S Sanger sequencing; 87% of the NGS results were ultimately determined to be the correct result. Overall, these data demonstrate that BIOTIA-ID is a highly accurate clinical-grade diagnostic tool with notable advantages over current culture- based diagnostics. Conflict of Interest Statement MCR, DCD, HLW, SR, XJS, JP, PFC, GF, CEM, CO, NBO and DNS are employees at Biotia, Inc.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Targeted next-generation sequencing: a promising approach for pathogen and antimicrobial resistance gene detection in urinary tract infections.Frontiers in microbiology · 2026
- Metagenomic sequencing enables accurate pathogen and antimicrobial susceptibility profiling in complicated UTIs in approximately four hoursNature Communications · 2025
- Metagenomic next-generation sequencing improves pathogen detection in culture-negative infections: a diagnostic performance study.Frontiers in microbiology · 2026
- Rapid diagnosis of common, undetected, and uncultivable bloodstream infections from positive blood cultures using Oxford Nanopore sequencing: a metagenomic pipeline analysisThe Lancet Microbe · 2026
- Comparative evaluation of metagenomic and targeted next-generation sequencing for pathogen detection in bronchoalveolar lavage fluid from patients with lower respiratory tract infections: a retrospective cohort study.Frontiers in cellular and infection microbiology · 2026
- BacT-Seq, a Nanopore-Based Whole-Genome Sequencing Workflow Prototype for Rapid and Accurate Pathogen Identification and Resistance Prediction from Positive Blood Cultures: A Feasibility StudyDiagnostics · 2026