Can Inertial Measurement Units Replace Common Sport Science Testing Equipment as an All-in-One Solution?
Drake Huff, Jacob Garrity, Daniel McIntosh, Robin Thorpe, Hugh Lamont, Jason Siegler
Integrative Human Performance Lab, College of Health Solutions,Arizona State University, Phoenix, AZ, USA. · Sun Devil Athletics,Arizona State University, Tempe, AZ, USA.
Key points
From the paper's conclusion- Lack of agreement between IMUs and the criterion devices suggest that at present, IMUs should not be used as a single, expedient solution during performance testing.
Abstract
PURPOSE: This pilot study evaluated the agreement between inertial measurement units (IMUs) and criterion standard performance assessment equipment (e.g., timing gates and force platforms). METHODS: Sixteen female Division 1 athletes completed a standard, preseason assessment battery including the 10-yard dash, Pro-Agility (5-10-5), countermovement jump, and a 5-3 multirebound jump wearing IMUs throughout the performance assessments to evaluate agreement with force platforms and timing gates. All testing took place in a climate-controlled collegiate weight room environment. Agreement between devices were evaluated separately for each assessment and measurement pair using repeated-measures limits of agreement analysis via the "SimplyAgree" package (v.0.2.1). Bias and limits of agreement were analyzed via method of variance estimates recovery with replicates selection applied. RESULTS: Inertial measurement units demonstrated a lack of agreement with criterion devices across all performance assessments (10-yard dash completion time, mean bias of -1.22 [0.29] s, and distance covered, mean bias of -4.09 [1.13] m); 5-10-5 completion time, mean bias of 0.80 [0.51] s, and distance covered, mean bias of 7.23 [1.56] m; countermovement jump height, mean bias of -13.12 [2.56] cm, and flight time, mean bias of -0.10 [0.02] s; and multirebound jump height, mean bias of -6.50 [2.65] cm). CONCLUSIONS: Lack of agreement between IMUs and the criterion devices suggest that at present, IMUs should not be used as a single, expedient solution during performance testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- IMU-based estimation of drop and squat jump metrics: criterion validity, agreement, and reliability.Computer methods in biomechanics and biomedical engineering · 2026
- Agreement of Wearable Inertial Sensors with Optoelectronic Motion Capture for Felge-to-Support Temporal Segmentation.Bioengineering (Basel, Switzerland) · 2026
- A comprehensive evaluation of an inertial sensor for High-Intensity shocks and vibration analysis in a real tennis contextMeasurement · 2026
- A Hybrid Ultra-Wideband and Inertial Measurement Unit Sensor System Can Accurately Measure the Sprinting Performance in Young Male Soccer Players.Journal of functional morphology and kinesiology · 2026
- Agreement and reliability of force-plate, smartphone-based, and wearable-sensor countermovement jump assessments for neuromuscular monitoring in male professional volleyball players.Frontiers in physiology · 2026
- Accelerometry for Gym-Based Training: Comparing Resistance Versus Plyometric Training.Sensors (Basel, Switzerland) · 2026