Individual Calibration of a Multiinput Wearable Device Improves Exercise Energy Expenditure Estimation During Intermittent High-Intensity but Not Resistance Exercise in an Athletic Female Population.
Rebekka Frazer, Christopher D Askew, Amy-Lee Bowler, Louise M Burke, Dominique Condo, Gregory R Cox, Krist Feka, Shona Halson,
School of Health, University of the Sunshine Coast, Sippy Downs, QLD, Australia. · Mary MacKillop Institute for Health Research, Australian Catholic University, Melbourne, VIC, Australia.
Key points
From the paper's conclusion- This study aimed to determine the accuracy of a multiinput wearable device (Actiheart 5) and commercially available accelerometer (GENEActiv) in the estimation of exercise energy expenditure (EEE) during intermittent high-intensity and resistance exercise sessions among 31 trained females.
Abstract
This study aimed to determine the accuracy of a multiinput wearable device (Actiheart 5) and commercially available accelerometer (GENEActiv) in the estimation of exercise energy expenditure (EEE) during intermittent high-intensity and resistance exercise sessions among 31 trained females. Data were collected over two testing sessions involving (a) measurement of resting metabolic rate, physique and a graded exercise test on a treadmill to enable individualized calibration of the wearables, and (b) A modified Bath University Rugby Union Shuttle Test followed by a resistance exercise session. GENEActiv and Actiheart EEE-derived measures, using both generic and individually calibrated algorithms, were compared against (a) indirect calorimetry for Bath University Rugby Union Shuttle Test and (b) indirect calorimetry plus the estimated anaerobic energy contribution based on blood lactate responses for resistance exercise. Equivalence was evaluated using predefined bounds of ±10% mean indirect calorimetry EEE. The use of individually-calibrated Actiheart algorithms improved estimation of EEE during Bath University Rugby Union Shuttle Test (mean bias 4.5 ± 60.4 kcal) compared with individually-calibrated GENEActiv algorithms (mean bias 69.5 ± 86.6 kcal), and equivalence with indirect calorimetry was achieved, although substantial individual error remained (95% limits of agreement -113.9 to 122.8 kcal and intraclass correlation coefficients, .62 [.34 to .80]). Individualized Actiheart algorithms provided equivalent group-level estimates of EEE during intermittent high-intensity exercise, whereas neither Actiheart nor GENEActiv demonstrated acceptable validity or equivalence against the reference method for resistance training, suggesting Metabolic Equivalents of Task may be a more practical method of estimating EEE.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of smartwatch-derived energy expenditure estimation during outdoor activities.Frontiers in digital health · 2026
- Feasibility of energy expenditure estimation during outdoor walking using multimodal in-ear sensors: a preliminary validation study against indirect calorimetryScientific Reports · 2026
- Optimal Wearing Position of Accelerometers for Monitoring Energy Expenditure in Tennis.International journal of sports physiology and performance · 2026
- Accelerometry-Based Machine Learning Estimation of Energy Expenditure and Physical Activity Intensity Classification in Daily Tasks.Sensors (Basel, Switzerland) · 2026
- Estimating running economy using wearable trunk accelerometry: a comparative analysis of three footwear conditions in highly trained runners.Sports biomechanics · 2026
- Absolute Agreement Between a Consumer Wearable and Research Grade Accelerometry in Free-Living Conditions: Comparison Study.JMIR formative research · 2026