Acoustic isolation of the Nasometer separation plate: Effects of plate geometry and microphone placement.
Elan Little, Kaurab Gautam, Ephraim Gutmark, Liran Oren
School of Engineering Education, MDE/IDES, Purdue University, West Lafayette, Indiana 47907, USA. · Department of Aerospace Engineering and Engineering Mechanics, University of Cincinnati, Cincinnati, Ohio 45221, USA.
Key points
From the paper's conclusion- This study quantifies acoustic isolation of the Nasometer separation plate from 100 to 7000 Hz, examining source amplitude, microphone position, and plate geometry.
Abstract
Nasometers compute nasalance using microphones on each face of a rigid separation plate held at the philtrum. The manufacturer of the Pentax Nasometer specifies 25 dB of channel separation, but no methodological details accompany this value. This study quantifies acoustic isolation of the Nasometer separation plate from 100 to 7000 Hz, examining source amplitude, microphone position, and plate geometry. Tonal sweeps were performed in an anechoic chamber with microphones on each plate face. Within the 350-750 Hz nasalance band, the oral-to-nasal sound pressure level (SPL) difference (ΔSPL) for the clinical plate ranged from 10 to 15 dB, substantially below the manufacturer's specification. Leakage was largely level-independent, reflecting acoustic geometry rather than source amplitude. Moving the microphones to the lateral plate edge further reduced acoustic isolation, with ΔSPL falling to 6-12 dB. A larger custom plate at a matched microphone distance improved ΔSPL to 16-22.5 dB. Schlieren imaging with spectral proper orthogonal decomposition confirmed edge diffraction as the dominant leakage mechanism. For the clinical plate, the measured separations correspond to leakage nasalance contributions of approximately 15%-24%, overlapping published normative oral-speech scores and indicating plate-induced crosstalk is a clinically meaningful source of bias in nasalance measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mind the Gap: How Velopharyngeal Gap Size Influences Consonant Accuracy.The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association · 2026
- Direct Time-Domain Eduction of Acoustic Liner Impedance in Turbulent Grazing Flows.Journal of fluid mechanics · 2026
- Effects of mask leakage characteristics on aerosol inhalability and deposition in the human nasal cavityPhysics of Fluids · 2026
- Acoustic Performance of Circular Silencers with Sequential Mixed-Perforation Liners: Experimental Insertion Loss and Maa Impedance AnalysisApplied Sciences · 2026
- Acoustic Optimization of Classroom Environments Using Oriented Strand Board Panels: Layout Strategy and Simulation ValidationBuildings · 2026
- Automated Assessment of Hypernasality in Motor Speech Disorders Using Nasal Cognate Distinctiveness and Nasal Posterior Probability.medRxiv : the preprint server for health sciences · 2026