Shima Abadi
This study quantifies the relationship between distributed acoustic sensing (DAS) and traditional hydrophone measurements of ship noise. Analyzing a cargo ship's transit recorded by a DAS array and a nearby hydrophone, a conversion factor of 177.7 ± 3.5 dB (30-50 Hz) was derived, relating DAS strain to hydrophone pressure. A comparison of this conversion factor with a few existing studies highlights the variability in reported values and methodologies, underscoring the need for more extensive analysis and dedicated research to fully characterize DAS calibration.