The Journal of the Acoustical Society of AmericaMaterials science

Bulk absorber acoustic characterization via the two-cavity impedance tube method

Anthony Vincent Ciletti, Janith Godakawela, Martha C. Brown, Bhisham Sharma

Michigan Technological University · Langley Research Center

Key points

From the paper's conclusion
  • This approach significantly improves predictive accuracy, validating the two-cavity impedance tube method as a robust and effective tool for the acoustic characterization of a wide variety of porous materials, including metallic and nonmetallic open-cell foams and additively manufactured lattice structures.

Abstract

The primary goal of this study is to investigate and refine the two-cavity impedance tube method for acoustic characterization of bulk porous materials, specifically addressing previously unexplained inaccuracies in the prediction of surface impedance and absorption coefficients. Unlike the conventional two-thickness approach, the two-cavity method requires only one sample thickness and involves conducting measurements at various air cavity depths behind the sample. The initial analyses revealed previously unidentified numerical instabilities, resulting in anomalous predictions of sound absorption at specific frequencies. Through systematic investigation and use of calculated data, the numerical origins of these anomalies are uncovered and a practical solution, involving the careful selection of cavity depths, is presented. This approach significantly improves predictive accuracy, validating the two-cavity impedance tube method as a robust and effective tool for the acoustic characterization of a wide variety of porous materials, including metallic and nonmetallic open-cell foams and additively manufactured lattice structures.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Bulk absorber acoustic characterization via the two-cavity impedance tube method — Science Skim