Characterization of IBEX LmAPD detectors at CEA for future low-noise NIR astronomy instruments
Jean Le Graët, Vincent Affatato, Marion Baumann, Olivier Boulade, Cyrille Delisle, Eloy Hernandez, Christian Ketchazo, Frederic Lemmel,
Key points
From the paper's conclusion- These results establish IBEX as a promising European large-format detector for future ultra-low-flux NIR instruments.
Abstract
Future near-infrared (NIR) astronomy missions dedicated to photon-starved science cases, in particular an all-sky astrometric survey extending the legacy of Gaia into the NIR, as identified within the ESA Voyage~2050 programme, require large-format detectors combining sub-electron effective read noise with very low dark current. Linear-mode avalanche photodiodes (LmAPDs) based on HgCdTe meet this need by multiplying the photo-generated charge by an avalanche gain before the readout stage, thereby reducing the relative contribution of the read noise. We report the first electro-optical characterization of an IBEX detector, a $2048\times2048$, \SI{15}{\micro\meter}-pitch HgCdTe LmAPD array developed by Leonardo with the European Space Agency and operated at \SI{80}{\kelvin} on a dedicated bench at CEA-IRFU. We first discuss the central difficulty of characterizing an APD array, the degeneracy between avalanche gain, quantum efficiency (QE), and conversion gain in the measured response, and we then separate the measurements into two categories. Among the quantities that are directly measurable without assumptions, we report a signal-to-noise ratio for a CDS measurement that exceeds that of a Euclid-type H2RG above \SI{8}{\volt} pixel bias under identical low-flux conditions, a photo-response non-uniformity stable at the $\sim$10\% level, and a quantum efficiency-to-excess-noise ratio (QEFR) of \num{0.40} at \SI{10.5}{\volt}. Among the quantities derived under an explicit set of assumptions, we obtain a conversion gain corresponding to a sense-node capacitance of \SI{27}{\femto\farad}, a quantum efficiency of $46\pm12\%$ at \SI{2.5}{\volt}, and an excess noise factor $F=1.15\pm0.14$ at \SI{10.5}{\volt}. These results establish IBEX as a promising European large-format detector for future ultra-low-flux NIR instruments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Linear-mode photon counting performance and intrinsic dark current in HgCdTe APDs for quantum optical applicationsarXiv · 2026
- Laboratory Characterization of a Ge-CCD Prototype for Future Near-Infrared Astronomical InstrumentationarXiv · 2026
- Recent advances of infrared avalanche photodiodes based on low-noise aluminum (antimony)-contained materials and their journey toward single-photon detectionAPL Photonics · 2026
- Characterization of the GIGAPYX-4600 CMOS visible image sensor in the context of high precision astrometryarXiv · 2026
- In Situ Bulk Passivation and Carrier Transport Modulation in Te-TeOx Films Enable Low-Noise Monolithic Near-Infrared Imagers.Advanced materials (Deerfield Beach, Fla.) · 2026
- Photometric parameter inversion and nonlinearity characterization of infrared focal plane arrays based on flat-field data.Optics express · 2026