Spatio-temporally modulated fluorescence imager for intraoperative nerve identification.
Jesung Park, Hyejin Yoo, Samuel S Streeter, John Grimble, Mark T Scimone, Gopi Maguluri, Jeffrey L Campbell, Madelyn O'Shaughnessy,
Physical Sciences, Inc., Andover, Massachusetts, United States. · Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States.
Key points
From the paper's conclusion- This innovative imaging technology enables high-contrast fluorescence visualization of nerve tissue under standard OR lighting and represents a significant step toward practical clinical implementation of FGS for enhanced nerve identification.
Abstract
SIGNIFICANCE: Fluorescence-guided surgery (FGS) based on nerve-labeling agents has the potential to enhance nerve identification during various operational procedures including orthopedic, craniofacial, and otolaryngological surgeries that involve complex and delicate nerve structures. A major challenge in FGS is the adverse impact of strong ambient light, which interferes with weak fluorescence signals, especially at visible wavelengths. Currently, this issue is mitigated by dimming or turning off the operating room (OR) lights during the fluorescence imaging procedure. However, this causes substantial disruption to the surgical workflow and reduces the potential for clinical adoption of FGS technologies. AIM: In this work, we develop a novel intraoperative fluorescence imager that is based on a spatio-temporal modulation (STM) approach to suppress interference from strong OR lights. APPROACH: The STM technology employed a line-scan imaging scheme that encodes the fluorescence signal into a distinctive spatial frequency within a narrow time window. By applying spatial frequency demodulation and time-gating methods, the imager effectively extracted the fluorescence signals by rejecting temporally constant and spatially uniform background OR lights. RESULTS: The performance of the imager in detecting nerve structures in realistic OR lighting conditions was validated during in vivo animal studies. Additional evaluation using ex vivo human nerve tissue specimens and perfused amputated human limbs further supported the clinical suitability and readiness. CONCLUSIONS: This innovative imaging technology enables high-contrast fluorescence visualization of nerve tissue under standard OR lighting and represents a significant step toward practical clinical implementation of FGS for enhanced nerve identification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time wide-field fluorescence lifetime imaging via single-snapshot acquisition for biomedical applicationsPhotoniX · 2025
- Label-Free Facial Nerve Identification During Parotidectomy Using Nerve Autofluorescence: An Initial Clinical Series.Cureus · 2026
- Precise optogenetic activation of peripheral motor nerves using patterned illumination.Journal of neural engineering · 2026
- A Protocol for Surgical Preparation of Rats for In Vivo Fiber Optic Photometry Using Genetically Encoded Fluorescent Biosensors.Methods and protocols · 2026
- Seeing deeper, seeing more: Complementary philosophy in the constructions of fluorescence imaging probes for surgical navigation.Colloids and surfaces. B, Biointerfaces · 2026
- Frozen agarose-assisted tissue preparation for stimulated Raman histology enables rapid intraoperative assessment of peripheral nerve integrity.Brain & spine · 2026