Spatial optimization of transthoracic diffuse optics for myocardial ischemia in mice: a Monte Carlo study.
Tao Yang, Guangqi Chen, Danni Wei, Yongle Wang, Sifan Chen, Jiayu Hu, Le Pan, Henggui Zhang,
Southwest Medical University, Key Laboratory of Medical Electrophysiology, Ministry of Education & Medical Electrophysiological Key Laboratory of Sichuan Province, Institute of Cardiovascular Research, Luzhou, China. · Nuclear Medicine and Theranostics Key Laboratory of Sichuan Province, The Affiliated Hospital of Southwest Medical University, Department of Nuclear Medicine, Luzhou, China.
Key points
From the paper's conclusion- An optimized S-D configuration was demonstrated for establishing a linear correlation between optical signal variations and ischemic severity. This study provides a theoretical framework toward diffuse optics for in vivo assessment of cardiac hemodynamics and tissue oxygenation in murine models.
Abstract
SIGNIFICANCE: Continuous, noninvasive assessment of myocardial ischemia in intact mouse models poses a significant technical challenge. Conventional diffuse optical techniques are mostly limited to ex vivo hearts or open-chest animal models due to severe signal attenuation and tissue interference caused by the complex thoracic anatomy. Empirical placement of photoelectric probes over the cardiothorax further undermines the sensitivity and specificity of cardiac signal detection. AIM: This study aims to systematically characterize photon transport dynamics within the mouse thorax, determine the optimal light Source-Detector (S-D) spatial configuration, and quantitatively evaluate the theoretical feasibility of transthoracic diffuse optics for detecting varying degrees of myocardial ischemia. APPROACH: Using a high-fidelity 3D voxelized model derived from realistic mouse anatomical data, we performed Monte Carlo photon transport simulations at 800 nm. A high-density virtual array of sources and detectors was deployed on the body surface to determine the optimal S-D positions for cardiac signal extraction. Myocardial ischemia was simulated by modulating the optical coefficients of myocardial tissue, enabling the investigation of the relationship between surface-captured optical signals and ischemia severity. RESULTS: The simulations identified an optimized S-D configuration that maximizes the detection sensitivity for deep myocardial signals while minimizing interference from overlying tissues. Notably, under this configuration, the diffuse optical signals collected at the body surface showed a strong linear correlation with the degree of myocardial ischemia. CONCLUSIONS: An optimized S-D configuration was demonstrated for establishing a linear correlation between optical signal variations and ischemic severity. This study provides a theoretical framework toward diffuse optics for in vivo assessment of cardiac hemodynamics and tissue oxygenation in murine models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- TissOP-Probe: An Integrated Measurement-Modeling Framework for Translating Ex Vivo Tissue Optical Properties into Diffuse Reflectance Probe Design Specifications.Bioengineering (Basel, Switzerland) · 2026
- Characterization of cardiac fibrosis and Fosl-2 associated arrhythmias with volumetric optoacoustic spectroscopyScientific Reports · 2026
- Diffuse environment imaging via non-ionising optical tomography and inverse radon reconstructionJournal of Optics · 2026
- The opportunities of using 1064 nm light source in diffuse optics systems for deep tissue monitoring: a systematic review2026
- Establishment and Optimization of a Mouse Model of Myocardial Ischemia-Reperfusion Injury.Journal of visualized experiments : JoVE · 2026
- Integration of an echocardiographic motion-management system into photon-based stereotactic arrhythmia radioablation planning.Physics and imaging in radiation oncology · 2026