Automated hemodynamic resuscitation system for computer-controlled norepinephrine, vasopressin, and fluid therapy in endotoxin-induced shock: a feasibility and physiological proof-of-concept study.

Kazumasu Sasaki, Kazunori Uemura, Hiroki Matsushita, Yuta Nakamura, Kenta Ohba, Yasuyuki Kataoka, Takuya Nishikawa, Kei Sato, Hidetaka Morita, Masahiro Otake, Nana Hiraki, Masafumi Fukumitsu, Toru Kawada, Kenji Sunagawa, Joe Alexander, Keita Saku

一句话结论 · In one sentence

This proof-of-concept study validates the feasibility and physiological performance of the system for the hemodynamic management of vasoplegic shock.

原始摘要(英文原文)· Original abstract
BACKGROUND: To support hemodynamic management in vasoplegic shock, we previously developed a closed-loop automated infusion system of norepinephrine (NE) and fluid to automatically restore arterial pressure (AP) and cardiac output (CO). To enhance the practical feasibility and efficacy of the system, we integrated a minimally invasive CO monitor and a closed-loop control of vasopressin (AVP) infusion to the system and validated the integrated system in dogs with endotoxin-induced shock. METHODS: Based on the circulatory equilibrium framework, the system directly controls systemic vascular resistance and stressed blood volume by titrating NE and Ringer's acetate solution (RiA), respectively, thereby restoring AP and CO. AVP is automatically initiated once infusion rate of NE is increased higher than 1 μg·kg⁻1·min⁻1. The minimally invasive CO monitor estimates CO (COes) by a machine-learning analysis of the peripheral AP contour. In eight anesthetized dogs, the system was implemented, and reference CO (COref) was measured using an aortic flow probe to calibrate COes and track reference hemodynamics. Endotoxin shock was induced via intravenous lipopolysaccharide infusions. After the target AP and COes were set to 70 mmHg and 132 (132-133) mL·min-1·kg-1, respectively, the system was activated. RESULTS: The lipopolysaccharide infusion significantly reduced AP from 82 (80-85) to 52 (50-56) mmHg and COref from 132 (125-146) to 90 (80-103) mL·min-1·kg-1, and increased the blood lactate level (LAC) from 21 (21-23) to 36 (32-38) mg·dL-1. Once the system was activated, infusions of NE and RiA were automatically initiated. Infusion of AVP initiated during the system control was associated with significant reduction in NE dose while maintaining AP. Within 5 min after system activation, AP and COes were recovered to >65 mmHg and >122 (122-123) ml·min-1·kg-1, respectively. The median absolute performance errors for AP and COes were <5%. At 60 min after system activation, AP and COref significantly increased to 72 (68-75) mmHg and 130 (127-137) ml·min-1·kg-1 and LAC significantly decreased to 26 (25-28) mg·dL-1 relative to the values observed at endotoxin shock. COes tracked directional changes in COref reasonably well. CONCLUSIONS: This proof-of-concept study validates the feasibility and physiological performance of the system for the hemodynamic management of vasoplegic shock.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Automated hemodynamic resuscitation system for computer-controlled norepinephrine, vasopressin, and fluid therapy in endotoxin-induced shock: a feasibility and physiological proof-of-concept study. — 科研速览 Science Skim