Morphological variations or transposition of the ventral lamina of the sixth cervical vertebra (C6) are well documented in horses. Radiography remains the primary modality for identifying these osseous variations, whereas scintigraphy provides a functional assessment of bone activity; however, its diagnostic accuracy for this condition has not been established. This retrospective single-center study evaluated the diagnostic performance of scintigraphy compared with radiography for detecting C6/C7 ventral laminar anomalies and determined an optimal C6:C7 uptake ratio cutoff. Thirty-four horses underwent both radiographic and scintigraphic examination. Radiography served as the reference standard, classifying horses as normal (n = 22) or abnormal (n = 12; unilateral n = 5, bilateral n = 7). Semiquantitative scintigraphic analysis was performed using a C6:C7 uptake ratio derived from background-corrected counts per pixel. The visual scintigraphic assessment demonstrated 75.0% sensitivity (95% CI: 42.8%-94.5%) and 72.7% specificity (95% CI: 50.9%-88.7%). Semiquantitative receiver-operating characteristic (ROC) analysis yielded an optimal C6:C7 ratio cutoff of 0.81 (area under the curve [AUC] = 0.762), providing 66.7% sensitivity and 81.8% specificity. The C6:C7 ratio was significantly higher in abnormal horses compared with normal horses for both the left (0.860 ± 0.149; p = 0.006) and right (0.812 ± 0.148; p = 0.035) sides. No significant differences within-subject side-to-side (left-right) C6:C7 ratio were detected. Scintigraphy demonstrated moderate diagnostic accuracy for detecting C6:C7 ventral laminar anomalies. A C6:C7 ratio threshold of 0.81 may serve as a practical adjunct screening parameter, though validation in larger populations is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Scintigraphic Characteristics of the Occipitoatlantoaxial Region in Clinically Sound Horses.Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association · 2026
- Inter-Reader and Inter-Modality Agreement for Radiographic and Magnetic Resonance Imaging Subchondral Bone Assessment in the Equine Proximal Phalanx Is Location- and Pattern-Dependent.Animals : an open access journal from MDPI · 2026
- Guttural Pouch Endoscopy Outperforms Radiography for Detection of Advanced Temporohyoid Osteoarthropathy Using Computed Tomography as the Reference Standard in 382 Horses.Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association · 2026
- Accuracy of Computed Tomography in Diagnosing Temporomandibular Joint Osteoarthritis Relative to Histopathological Findings—An Ex Vivo Study of 41 HorsesAnimals · 2026
- Diagnostic Performance of Digital Tomosynthesis for Detecting Osteophytes and Subchondral Bone Changes in the Equine Distal Interphalangeal and Metacarpophalangeal Joints.Animals : an open access journal from MDPI · 2026
- Evaluation of Digital Tomosynthesis for Detecting Articular Cartilage Lesions in Equine Distal Interphalangeal and Metacarpophalangeal Joints: Comparison with Computed Tomography Arthrography.Animals : an open access journal from MDPI · 2026