Potassium EDTA Contamination Causing Preanalytical Errors in Canine and Feline Serum Samples.
Emma M Strage, Anders Larsson, Anna Hillström, Gunne Eriksson, Johan Olausson
Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden. · Department of Medical Sciences, Section of Clinical Chemistry, Uppsala University, Uppsala, Sweden.
Key points
From the paper's conclusion- These findings emphasize that even small amounts of kEDTA can compromise diagnostic accuracy. This underscores the importance of strict compliance with recommended blood collection order and highlights the value of direct EDTA measurements in veterinary laboratory diagnostics.
Abstract
BACKGROUND: Contamination of serum samples with the anticoagulant potassium ethylenediaminetetraacetic acid (kEDTA) constitutes a critical pre-analytical error in veterinary diagnostics and can lead to potentially life-threatening misinterpretation of biochemical test results. OBJECTIVES: To develop and validate a method for quantifying EDTA in canine and feline sera. A second aim was to evaluate the effect and prevalence of kEDTA contamination in canine and feline serum samples. METHODS: A copper-PAN-based automated method for quantifying EDTA in canine and feline sera was developed. Canine and feline serum samples admitted together with EDTA tubes were analyzed for kEDTA contamination. RESULTS: The measuring range was set to 0.03-0.4 mM, with a coefficient of variation of < 13.1% and acceptable linearity upon dilution (75%-118%). Spiking experiments demonstrated that kEDTA caused a dose-dependent increase in potassium and decreases in calcium, magnesium, iron, and zinc, with iron and zinc most profoundly affected. The allowable total error was exceeded at low kEDTA concentrations, even when analytes remained within reference intervals. A prevalence study of 1065 serum samples submitted with kEDTA tubes revealed contamination rates of 1.1% in dogs and 1.8% in cats. CONCLUSIONS: These findings emphasize that even small amounts of kEDTA can compromise diagnostic accuracy. This underscores the importance of strict compliance with recommended blood collection order and highlights the value of direct EDTA measurements in veterinary laboratory diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine learning for the identification of mild to moderate EDTA contamination of serum samples.Annals of clinical biochemistry · 2026
- 239 Masking Effect of K2-EDTA Contamination on Iron PaneAmerican Journal of Clinical Pathology · 2026
- A-411 Evaluation of Point-of-Care Creatinine Analyzers: eGFR Categorization Accuracy for Safe Contrast AdministrationClinical Chemistry · 2026
- Point-of-care troponin I assay has acceptable performance detecting clinically important canine myocardial injury but reduced precision at low concentrations.American journal of veterinary research · 2026
- Spectrum of Preanalytical Laboratory Errors in Clinical Biochemistry Laboratory in a Tertiary Care Center in Nepal.Kathmandu University medical journal (KUMJ) · 2025
- Spurious Hyperkalemia Without Hemolysis: A Case-Based Presentation of Preanalytical Errors and Diagnostic Pitfalls.Diagnostics (Basel, Switzerland) · 2026