Transfusion medicine (Oxford, England)

Extended validation of transport conditions of thawed PF24 units.

Dmitry Zlobin, Martin Jerez, Farrah Roberts, Jennifer Miller, Maria Proytcheva, Debra Smith, Yigit Baykara

Department of Pathology, University of Arizona College of Medicine, Tucson, Arizona, USA.

Key points

From the paper's conclusion
  • A 6-h cooler time of thawed PF24 does not accelerate coagulation factor degradation or compromise sterility over an extended 5-day shelf life. These findings validate flexible inventory return policies, allowing blood banks to reduce product waste.

Abstract

BACKGROUND: The transport and storage conditions of thawed plasma are not strictly regulated by the regulatory bodies and applying the red blood cell transport standard of 1-10°C to recently thawed plasma often results in high discard rates. This study evaluated the extended 120-h (5-day) coagulation factor stability and sterility of thawed plasma frozen within 24 h after collection (PF24) following a 6-h transport cooler simulation. STUDY DESIGN AND METHODS: Fourteen PF24 units (8 group O, 6 group B) were thawed at 30-37°C and assigned as control (n = 7, direct 1-6°C refrigeration) or experiment (n = 7) units. Experiment units were held at room temperature for 30 min, stored in validated transport coolers for 6 h, and then transferred to 1-6°C refrigeration. Measurements of temperature, prothrombin time (PT), Factor V (FV) activity, and Factor VIII (FVIII) activity were conducted at 0-, 6-, 24-, and 120-h post-thaw. Sterility testing was performed at 0- and 120-h using automated aerobic and anaerobic blood cultures. RESULTS: No statistically significant differences were observed between control and experiment units at 120-h for mean PT (15.09 s vs. 15.16 s, p = 0.44), FV activity (81.14% vs. 74.57%, p = 0.23), or FVIII activity (61.86% vs. 53.00%, p = 0.22). Delta analysis (Δ120h-0h) confirmed equivalent factor decay rates between groups. All bacterial cultures showed no growth at 120-h. CONCLUSION: A 6-h cooler time of thawed PF24 does not accelerate coagulation factor degradation or compromise sterility over an extended 5-day shelf life. These findings validate flexible inventory return policies, allowing blood banks to reduce product waste.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Extended validation of transport conditions of thawed PF24 units — Science Skim