Convolutional neural network for red blood cell transfusion prediction: A machine learning based study.
Liyun Zheng, Jiyuan Ma, Mengyun Deng, Yiming Ma, Yuan Zhang, Lihua Wang, Xiaofei Li
Department of Blood Transfusion, Beijing Friendship Hospital, Capital Medical University, Beijing, China. · Medical Digital Intelligence Innovation Center, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Key points
From the paper's conclusion- To tackle these persistent clinical limitations, we developed a workflow‐adapted clinical decision support tool: a one‐dimensional convolutional neural network (1D CNN) trained on routinely acquired haematological and clinical variables to stratify inpatient RBC transfusion volume categories.
Abstract
BACKGROUND: Subjective, inconsistent clinician judgement on red blood cell (RBC) transfusion demand causes unnecessary blood wastage, increased perioperative safety risks, and poorly balanced hospital blood inventory. To tackle these persistent clinical limitations, we developed a workflow-adapted clinical decision support tool: a one-dimensional convolutional neural network (1D CNN) trained on routinely acquired haematological and clinical variables to stratify inpatient RBC transfusion volume categories. METHODS: Using a retrospective cohort of 7,250 patients from Beijing Friendship Hospital (April 2024-June 2025), we trained a 1D CNN on 19 standardised pre-transfusion variables to predict transfusion volume categories (1, 2, 3, 4, ≥5 units). The model was optimised with Adam and evaluated on a 30% hold-out test set. Comprehensive characterisation of the cohort's baseline clinical features was also performed to clearly define the transfusion contexts and clinical indications of the study population. RESULTS: On the 30% hold-out test set, the 1D CNN reached an overall accuracy of 0.7314 and converged without overfitting. The model accurately identified the predominant 2 units transfusion class (68.03% of cases, precision 0.7314). However, performance was limited in minority classes (≥5 units and 3 units), which showed low prevalence (< 5%) and overlapping haemoglobin values (60-80 g/L), indicating a critical safety limitation. CONCLUSIONS: The 1D CNN reliably forecasts routine transfusion requirements in a single-center setting but under-detects high-volume transfusion events. External validation across diverse clinical centers, targeted data enrichment for minority classes, and development of indication-specific sub-models are mandatory to improve the model's generalizability and clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Explainable machine learning models for early prediction of acute kidney injury after cardiac surgeryInternational Urology and Nephrology · 2025
- Analysis of the Efficacy of Red Blood Cell Transfusion in Very Low Birth Weight Infants and Construction of a Prediction ModelIndian Journal of Hematology and Blood Transfusion · 2026
- Efficient convolutional neural networks for acute lymphoblastic leukaemia prediction in computer visionScientific Reports · 2025
- Prediction of acute kidney injury at the end of cardiac surgery using routine perioperative variables: a pre-specified benchmark of 210 machine learning combinationsFrontiers in Medicine · 2026
- The transformative power of artificial intelligence and machine learning in blood banking/transfusion medicine: A vein-to-vein approach from blood collection to transfusion services: On behalf of the AABB Foundation.Transfusion · 2026
- Use of machine learning models to predict mortality in dialysis patientsFrontiers in Public Health · 2025