From the paper's conclusion
  • Late atrial arrhythmia after heart transplantation is usually attributed to rejection, and the donor-recipient anastomosis is assumed to isolate the native pulmonary venous cuff.

Abstract

Late atrial arrhythmia after heart transplantation is usually attributed to rejection, and the donor-recipient anastomosis is assumed to isolate the native pulmonary venous cuff. We mapped it in three recipients treated with pulsed field ablation. In the first, native posterior wall electrograms cycled at half the tachycardia cycle length and conducted intermittently to the donor atrium until anastomotic ablation isolated them. The second had septal reentry despite a durable anastomosis; the third had reconnection of previously isolated pulmonary veins. Rejection was excluded in all. Although limited to three patients, these findings support mapping the anastomosis before attributing arrhythmia to rejection.