Optimized Strategy for Improving the Accuracy of Determining Left Bundle Branch Capture.
Guoqing Xu, Tao Yu, Changqing Li, Haibo Yu, Kun Na, Baige Xu, Yang Gao, Min Wu,
State Key Laboratory of Frigid Zone Cardiovascular Disease, Cardiovascular Research Institute and Department of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.
Key points
From the paper's conclusion- Selecting ΔLBBpo-V6RWPT for patients with LBBpo and ΔV6RWPT for those without LBBpo may help classify LBB capture in unclassified LBBAP with narrow QRS complexes. Diagnostic accuracy in this population requires prospective validation.
Abstract
BACKGROUND: The accuracy of current ECG criteria for left bundle branch (LBB) pacing (LBBP) remains inadequate. OBJECTIVES: To establish an optimized strategy to distinguish LBBP from left ventricular septal pacing (LVSP) in patients with a narrow QRS complex. METHODS: LBBpo-V6RWPT, Native-V6RWPT, and Paced-V6RWPT were measured from LBB potential (LBBpo) onset, intrinsic QRS onset, and stimulus end to the R-wave peak in V6, respectively. ΔV6RWPT and ΔLBBpo-V6RWPT were defined as Paced-V6RWPT minus Native-V6RWPT and Paced-V6RWPT minus LBBpo-V6RWPT. Receiver operating characteristic analysis identified optimal cut-offs for these two differences, Paced-V6RWPT, and the V6-V1 interpeak interval in patients with transition-confirmed capture. Areas under the curves (AUCs) were compared by LBBpo status. RESULTS: LBBP was confirmed in 292 (61.6%) of 474 patients with LBBAP. The optimal cut-off values of ΔLBBpo-V6RWPT, ΔV6RWPT, Paced-V6RWPT, and the V6-V1 interpeak interval for determining LBBP were 6 ms, 30 ms, 67 ms, and 31 ms, respectively. In 211 of 292 patients, LBBpo was recorded and the ΔLBBpo-V6RWPT criterion achieved the largest AUC (1.000), with 98.5% sensitivity and 99.5% specificity. LBBP was misclassified as LVSP by the ΔV6RWPT criterion in 3 patients but was correctly identified by the ΔLBBpo-V6RWPT criterion. In 81 of 292 patients, LBBpo was not recorded and the ΔV6RWPT criterion showed the largest AUC (0.990), with 98.8% sensitivity and 97.3% specificity. CONCLUSIONS: Selecting ΔLBBpo-V6RWPT for patients with LBBpo and ΔV6RWPT for those without LBBpo may help classify LBB capture in unclassified LBBAP with narrow QRS complexes. Diagnostic accuracy in this population requires prospective validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Left Bundle Branch Capture During Left Bundle Branch Area Pacing: A Diagnostic Accuracy Systematic Review.Pacing and clinical electrophysiology : PACE · 2026
- A Novel Method for Assessing Left Bundle Branch Capture Using the Bidirectional Conduction Time Difference Between Left Bundle Branch Area Pacing and Coronary Sinus Leads.Heart rhythm · 2026
- The flexibility of delayed fluoroscopic left ventricular angiography in periprocedural real-time visualization of the lead tip in left bundle branch pacing.Heart rhythm O2 · 2026
- Machine learning can detect left bundle branch area capture from individual-beat lead-restricted ECGsEuropean Heart Journal · 2026
- Challenges in left bundle branch area pacing in children and congenital heart disease: technical limitations, diagnostic pitfalls, and physiologic insights.European heart journal open · 2026
- Quantitative CT Lead Localization Reveals Proximal Left Bundle Targeting Facilitates Superior Physiologic Pacing.Heart rhythm · 2026