Neurogastroenterology and motility

FLIP Measurements Predict Short-Term Outcomes After Singular EsoFLIP Dilation in Patients With Achalasia.

Johann Stuby, Valeria Schindler, Joel Schnellmann, Jessica Martinez, Amanda Bianca, Daniel Pohl

Department of Gastroenterology and Hepatology, Zurich University Hospital, Zurich, Switzerland. · Department of Internal Medicine, Stadtspital Triemli, Zurich, Switzerland.

Key points

From the paper's conclusion
  • Delta values in FLIP metrics, particularly ΔEGJ-Dia and ΔEGJ-CSA, predicted excellent short-term symptomatic response. These findings indicate that intra-procedural FLIP panometry may help assess treatment adequacy during EsoFLIP dilation.

Abstract

BACKGROUND: FLIP enables real-time measurement of esophagogastric junction (EGJ) dimensions and pressures during dilation. While FLIP metrics predict outcomes after pneumatic dilation, POEM, and myotomy, their predictive value following EsoFLIP dilation remains unknown. This study identified FLIP measurements predicting short-term outcomes after EsoFLIP dilation in patients with achalasia. METHODS: Treatment-naïve patients undergoing singular EsoFLIP dilation (2017-2025) were analyzed. EGJ diameter (EGJ-Dia) and cross-sectional area (EGJ-CSA) were measured at 70 mL, distensibility index (EGJ-DI) and balloon pressure (EGJ-BP) at 60 mL, pre- and post-dilation. Primary outcome was excellent short-term symptomatic response at 4 weeks (Eckardt score ≤ 1). RESULTS: Seventy-nine patients (38% female, median age 52 years, achalasia type 1: 8%, type 2: 87%, type 3: 5%) were included. Symptomatic response was 81% (ES ≤ 3 or Δ ≥ 3) and 46% (ES ≤ 1); objective response 67%. Median ES decreased from 6 (IQR 4-7) to 2 (IQR 0-4). Median EGJ-Dia increased from 10 mm to 17 mm, EGJ-CSA from 72 mm2 to 220 mm2, and EGJ-DI from 1.4 mm2/mmHg to 5.8 mm2/mmHg, while EGJ-BP decreased from 31 mmHg to 24 mmHg (all p < 0.001). Among 51 patients with complete data, ΔEGJ-Dia70 (AUROC 0.77, cut-off ≥ 6.3 mm) and ΔEGJ-CSA70 (AUROC 0.75, cut-off ≥ 129.3 mm2) showed highest predictive performance. ΔEGJ-DI60 showed moderate performance (AUROC 0.65), while ΔBP60 was non-discriminative (AUROC 0.45). CONCLUSION: Delta values in FLIP metrics, particularly ΔEGJ-Dia and ΔEGJ-CSA, predicted excellent short-term symptomatic response. These findings indicate that intra-procedural FLIP panometry may help assess treatment adequacy during EsoFLIP dilation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

FLIP Measurements Predict Short-Term Outcomes After Singular EsoFLIP Dilation in Patients With Achalasia — Science Skim