Portable Ultra-Low-Field MRI in Outpatient Neurology: An Examination of Clinical Performance and Patient Experience.
Laszlo Mechtler, Sameer Ahmad Ansari, Jamal Derakhshan, Edmond Knopp, Nandor Pinter, Mohamad Asaad Nasri, Gincy Samuel
Dent Neurologic Institute, Buffalo, New York, USA. · Department of Radiology (Interventional Neuroradiology), Neurological Surgery, Ken and Ruth Davee Department of Neurology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.
Key points
From the paper's conclusion- In outpatient neurology practices, pMRI images demonstrated high clinical concordance with sMRI for identifying the presence or absence of structural brain abnormalities and were strongly preferred by patients. These findings support the use of pMRI as a practical point-of-care imaging tool for neurology patients, enabling timely access to structural neuroimaging during the clinical encounter.
Abstract
BACKGROUND AND PURPOSE: Brain magnetic resonance imaging (MRI) is an essential component for outpatient neurological evaluation, though access to timely imaging at the point of care is not feasible for most outpatient neurology practices. Portable ultra-low-field MRI systems offer a potential solution, but studies describing their clinical performance in routine outpatient neurology practice remain limited. This study evaluated clinical concordance and patient experience of portable MRI (pMRI) compared to standard-of-care MRI (sMRI) in independent neurology practices. METHODS: In this prospective, multicenter study, adults presenting to outpatient neurology clinics and requiring clinically indicated brain MRI completed imaging with both pMRI (0.064 T) and sMRI (91% 3 T, 9% 1.5 T) in the neurology clinic. All examinations were independently reviewed by board-certified neuroradiologists in a blinded, randomized fashion without access to clinical history. The primary endpoint was patient-level concordance between modalities for the presence or absence of abnormal findings. Discordant cases underwent post hoc unblinded paired review with clinical history to assess clinical significance. Secondary endpoints included patient-reported experience, assessed using a structured questionnaire evaluating noise, comfort, claustrophobia, anxiety, and overall experience on 10-point Likert scales, as well as modality preference. RESULTS: Among 125 participants imaged for common outpatient indications, including headache (40%), cognitive impairment or dementia (16%), multiple sclerosis follow-up (16%), and tumor surveillance (16%), portable and sMRI demonstrated 92% concordance on blinded review. Following clinically informed post hoc review, concordance increased to 98%. pMRI was rated more favorably across all patient experience domains (p < 0.001), and participants preferred pMRI (61%) over sMRI (14%) by a 4:1 ratio. CONCLUSIONS: In outpatient neurology practices, pMRI images demonstrated high clinical concordance with sMRI for identifying the presence or absence of structural brain abnormalities and were strongly preferred by patients. These findings support the use of pMRI as a practical point-of-care imaging tool for neurology patients, enabling timely access to structural neuroimaging during the clinical encounter.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Portable ultra-low field MRI in neurocritical care and intensive care units: A systematic review of diagnostic performance and feasibility.Emergency radiology · 2026
- Ultra-low-field portable MRI in neuroscience: Current status and future directionsJournal of Neuroradiology · 2026
- Portable ultra-low-field MRI in Africa: an access technology in search of an evidence base built without a safety net.European journal of radiology · 2026
- Patient and Family Perspectives on Point-of-Care Low-Field Brain Magnetic Resonance Imaging for Children in the Emergency Department, Intensive Care Unit, and Hospital Setting.Pediatric neurology · 2026
- Feasibility, image quality, and analytic usability of mobile 64 mT ultra-low-field MRI for infant brain imaging at 3 and 12 months in southern Malawi.Journal of magnetic resonance open · 2026
- Diagnostic performance of ultra-low field neurological magnetic resonance imaging: a systematic review protocol.BMJ open · 2026