Study on Safe Filler Injection Techniques Using Cutting-Edge Ultrasound Technology.
Won Lee, Benjamin Ascher, Kyu-Ho Yi, Ji-Soo Kim, Audrey Melin, Seong Hwan Kim
Yonsei E1 Plastic Surgery Clinic Anyang South Korea. · Think-In Tech Paris France.
Key points
From the paper's conclusion- The finger-held Doppler ultrasound system (SIBUS-IN) enabled real-time visualization of vascular structures during hyaluronic acid filler injection and was feasible for clinical use in nasolabial fold correction. In this limited observational cohort, the technique was well tolerated and not associated with immediate adverse events. However, the present study was not designed to demonstrate safety superiority or complication prevention; controlled comparative studies are required to determine whether this approach offers measurable advantages in safety or outcomes over conventional injection techniques.
Abstract
BACKGROUND: Recently, the development of an ultrasound device connected to a finger probe has enabled real-time ultrasound-guided filler injection. We aimed to evaluate the feasibility, clinical applicability, and patient satisfaction associated with the use of a novel real-time finger-held Doppler ultrasound system as a guide for hyaluronic acid filler injection. METHODS: The SIBUS-IN probe was attached to the fourth finger of the left hand, and hyaluronic acid filler was injected with the right hand. RESULTS: A total of 33 patients underwent treatment for nasolabial folds, with an average injection of 0.98 mL (0.5-2) of Lorient No. 4 hyaluronic acid filler on the left side and 0.95 mL (0.5-1.5) of the same hyaluronic acid filler on the right side. Two weeks posttreatment, 22 out of 33 patients responded "very satisfied," while 11 patients responded "satisfied." All patients reported satisfactory results, with a mean satisfaction score of 2.67. No vascular complications were reported. CONCLUSIONS: The finger-held Doppler ultrasound system (SIBUS-IN) enabled real-time visualization of vascular structures during hyaluronic acid filler injection and was feasible for clinical use in nasolabial fold correction. In this limited observational cohort, the technique was well tolerated and not associated with immediate adverse events. However, the present study was not designed to demonstrate safety superiority or complication prevention; controlled comparative studies are required to determine whether this approach offers measurable advantages in safety or outcomes over conventional injection techniques. LEVEL OF EVIDENCE STATEMENT: Level III.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Multimodal Ultrasound Assessment Framework for Suspected Vascular Compromise Following Hyaluronic Acid Filler Injection: A Retrospective Six-Patient Case SeriesAesthetic Surgery Journal Open Forum · 2026
- Ultrasound‐Assisted Facial Filler Injection: Vascular Mapping, Real‐Time Guidance, and Technical ConsiderationsDermatological Reviews · 2026
- Pre-Injection Doppler Mapping Versus Landmark Guidance for Lower Facial Hyaluronic Acid Injection in a Prospective Safety Study.Journal of visualized experiments : JoVE · 2026
- Assessment of Safety and Tissue Integration of PEGDE-Based Hyaluronic Acid Filler for Severe Nasolabial Folds: A Prospective Observational Study with Biophysical and Ultrasound EvaluationCosmetics · 2025
- Clinical features associated with HFUS-defined vascular occlusion after hyaluronic acid facial injections: a retrospective exploratory study.Journal of cosmetic and laser therapy : official publication of the European Society for Laser Dermatology · 2026
- Perceived User Experience, Comfort, and Ergonomics of an Add-on Backstop for Hyaluronic Acid Filler Injections: A Simulated-Use Study in Aesthetic Healthcare Professionals.Clinical, cosmetic and investigational dermatology · 2026