Usability and Feasibility of a Contactless Communication Support Application for Patients Undergoing Noninvasive Positive‐Pressure Ventilation
Taro Ozaki, Tatsuya Hayasaka, Kazunori Sato, Kenya Yarimizu, Ryuto Yokoyama, Masahiro Kuroki, Kiyotaka Soekawa, Takehiro Goto,
Key points
From the paper's conclusion- These findings support the potential utility of the contactless communication application as a nursing care technology to facilitate communication while minimizing patient burden.
Abstract
Aim To evaluate the usability and patient experience of a contactless communication support application for intensive care unit (ICU) patients receiving noninvasive positive‐pressure ventilation (NPPV) and examine the feasibility of maintaining oxygenation during application use. Methods In this prospective, single‐group observational feasibility study, 27 conscious ICU patients receiving NPPV used a tablet‐based contactless communication application for approximately 5 min. The application, developed using MediaPipe, enabled patients to select on‐screen options through fingertip movements without removing the mask. After use, patients completed the User Experience Questionnaire (UEQ) and a satisfaction survey. Peripheral oxygen saturation (SpO 2 ) was continuously monitored during application and compared within the same patients with SpO 2 values during brief conventional verbal communication requiring temporary removal of the NPPV mask under clinically stable conditions. Results UEQ scores were positive across all six domains. The overall satisfaction was favorable, with most patients reporting that the application facilitated communication and helped during NPPV. SpO 2 values during application use were similar to the pre‐use baseline values, whereas the levels during conventional communication requiring temporary mask removal were lower. Given the observational design, these findings are exploratory. Conclusions As an exploratory and observational finding, app‐assisted communication may help prevent decreases in SpO 2 , as the application enabled patient–clinician interaction during NPPV without the need for temporary mask removal. These findings support the potential utility of the contactless communication application as a nursing care technology to facilitate communication while minimizing patient burden. Broader clinical implementation warrants optimizing system efficiency and establishing training programs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- VoiceLove for patient-family communication in the ICU: a usability study of a novel voice messaging app.Frontiers in medicine · 2026
- Response to awake prone positioning in ICU patients with COVID-19 differs according to oxygenation interface: a prospective cohort studyThe Egyptian Journal of Critical Care Medicine · 2026
- Perception and accuracy of an AI-based contactless wellness screening system in dental setting; a cross-sectional study.The Saudi dental journal · 2026
- Exploring the acceptability of a lip-reading app in acute and critical care: Perspectives from patients with tracheostomies, relatives and healthcare professionals.Intensive & critical care nursing · 2026
- Non-Contact SpO2 Estimation Using Camera-Based Photoplethysmography: A Machine Learning Approach on EdgeSymmetry · 2026
- Utilization of a smartphone-based app for N95 respirator fit recommendations: A feasibility study assessing app respirator selection accuracy and usability compared to standard fit test processes.Journal of occupational and environmental hygiene · 2026