Deep Learning-Based Detection of Sessile Serrated Lesions in Colonoscopy Images: Optimization of a YOLOv3 Framework With Mucus Cap Feature Enhancement for Sessile Serrated Lesion Detection.
Hongna Lu, Pan Jiang, Tianyin Chen, QinQin Hu, Jiahua Wu, Xi Deng, Mengyao Ge, Ting Weng,
Department of Gastroenterology, The Affiliated LiHuili Hospital of Ningbo University, Ningbo, China. · Department of Neurology, The 906th Hospital of Joint Logistics Support Force of PLA, Ningbo City, Zhejiang Province, China.
Key points
From the paper's conclusion- Lesion‐level detection improved from 77.4% with the conventional model to 95.0% after incorporation of mucus cap screening, representing an improvement of 17.6%, with detection rates of 95.9% for mucus cap–free lesions and 98.4% for mucus cap–containing lesions.
Abstract
BACKGROUND AND AIM: Sessile serrated lesions (SSLs) are difficult to detect during colonoscopy via standard white-light imaging (WLI) because they are flat, have indistinct borders, and are often hidden by mucus caps. Although narrowband imaging (NBI) can help, its effectiveness is inconsistent. This study evaluated the feasibility of an artificial intelligence (AI)-assisted approach incorporating mucus cap features and both WLI and NBI for SSL detection and diagnosis. METHODS: This study developed an AI model for SSL detection by training it on 1980 colonoscopic images (2023-2025). The model enhances standard detection frameworks by specifically integrating mucus cap features and optimizing WLI performance. Model performance was evaluated using detection rate, accuracy, and AUC. RESULTS: At the image level, the SSL detection model achieved an accuracy of 98.7% (sensitivity 100.0%, specificity 97.4%). Lesion-level detection improved from 77.4% with the conventional model to 95.0% after incorporation of mucus cap screening, representing an improvement of 17.6%, with detection rates of 95.9% for mucus cap-free lesions and 98.4% for mucus cap-containing lesions. For morphology-based typing, the WLI-based model achieved an accuracy of 85.8% (AUC 0.89), whereas the NBI-based model showed superior performance with an accuracy of 91.6% (AUC 0.94). CONCLUSIONS: This study provides real-world clinical evidence validating AI-based models for SSL detection and diagnosis. Although representing an incremental step rather than a novel framework, such evidence is essential for improving model generalizability and enabling stable extrapolation across clinical settings. Further prospective and multicenter studies are required before reliable clinical deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence for the Detection of Small Bowel Lesions and Neoplasia: A Scoping Review.Cureus · 2026
- Report-Guided Semi-Supervised Learning for Scalable Prostate Cancer Detection on Biparametric MRI: Multicenter Prospective Validation and Multimodal IntegrationmedRxiv · 2026
- Improved Efficiency and Lesion Detection in Small Bowel Capsule Endoscopy Using the Open‐Source Artificial Intelligence Model SEE‐AIDEN Open · 2026
- Enhanced Esophageal Cancer Detection Using Spectrum‐Aided Vision Enhancer: A Comparative Study of White Light Imaging, Narrow‐Band Imaging, and Algorithmic Narrow‐Band Imaging‐Like ImagingDEN Open · 2026
- Impact of expert-curated video training data on computer-aided detection of sessile serrated lesions: a retrospective study in Korea.Clinical endoscopy · 2026
- Diagnostic Performance of Multimodal Artificial Intelligence in Differentiating Ocular Surface Squamous Neoplasia from Benign Lesions: A Retrospective Diagnostic Accuracy Study.Diagnostics (Basel, Switzerland) · 2026