Translucency and Masking Ability of CAD/CAM Milled Denture Base Resins of Different Shades and Thicknesses Against Metal Substrates.
Junning Liu, Rui Guo, Chenmin Yao, Jiakang Zhu, Cui Huang
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
Key points
From the paper's conclusion- Masking ability significantly increased with greater material thickness, a trend closely associated with reduced translucency. It was also influenced by both the resin shade and the metal substrate. The P3 shade provided the best masking ability for the tested gold-colored brass substrate. Under the present in vitro conditions, the tested silver-colored pure titanium substrate generally produced lower color differences than the tested gold-colored brass substrate.
Abstract
OBJECTIVE: To evaluate the translucency and masking ability of CAD/CAM milled denture base resins of different shades and thicknesses against gold- and silver-colored metal substrates. MATERIALS AND METHODS: Two independent experiments were conducted using separate specimens. Circular specimens (Φ10 mm) were fabricated from five shades (P1-P5) of CAD/CAM milled denture base resin at thicknesses of 1, 2, 3, and 5 mm (n = 8). For the 1-, 2-, and 3-mm specimens, the color coordinates were measured against white and black backgrounds, as well as gold- and silver-colored metal substrates. The 5-mm specimens superimposed on the black background were defined as the baseline color reference for each shade. The translucency parameter (TP00) was calculated based on measurements against white and black backgrounds, and the color difference (ΔE00), which represents the masking ability of the respective specimen, was calculated by comparing measurements against the metal substrates with the corresponding baseline color reference. Analysis of variance was used for statistical analysis, and exploratory correlation analyses were used to assess the association between baseline color coordinates and ΔE00 (α = 0.05). RESULTS: Both TP00 and ΔE00 values significantly decreased with increasing thickness for all shades, and all thickness-related ΔTP00 values exceeded the translucency acceptability threshold (TAT = 2.62). For the gold-colored metal substrate, the ΔE00 values at 1 mm exceeded the acceptability threshold (AT = 2.8) for all shades. At 2 mm, the ΔE00 values were below AT for the P1 and P3 shades but remained above AT for the other shades. At 3 mm, the ΔE00 values were below AT but remained above the perceptibility threshold (PT = 1.1) for P1-P4, whereas P5 remained slightly above AT. For the silver-colored metal substrate, the ΔE00 values at 1 mm exceeded AT for all shades. At 2 mm, they were below AT but remained above PT for all shades, whereas at 3 mm, they were below PT for all shades except P2. Generally negative correlations were observed between the color coordinates and ΔE00 values for the gold-colored metal substrate, whereas positive correlations were mainly observed for the silver-colored metal substrate. CONCLUSIONS: Masking ability significantly increased with greater material thickness, a trend closely associated with reduced translucency. It was also influenced by both the resin shade and the metal substrate. The P3 shade provided the best masking ability for the tested gold-colored brass substrate. Under the present in vitro conditions, the tested silver-colored pure titanium substrate generally produced lower color differences than the tested gold-colored brass substrate. CLINICAL SIGNIFICANCE: Under the present in vitro conditions, a resin thickness of 2 mm may be considered a practical option for masking the tested silver-colored pure titanium substrate. For the tested gold-colored brass substrate, masking at 2 mm was shade-dependent; therefore, careful shade selection or increased resin thickness may be required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Thickness in the Color Masking Ability of Different Types of Computer-Aided Design and Manufacturing Ceramics.Clinical and experimental dental research · 2026
- Multidimensional instrumental and visual evaluation of metamerism in single-shade resin composites: effects of color-matching technology, underlying color, thickness, and translucency.Odontology · 2026
- Optical properties and staining susceptibility of single-shade composite resins and their conventional counterparts.General dentistry · 2026
- Influence of Different Materials for Extrinsic Characterization on the Properties of CAD-CAM Denture Base Resins: A Systematic Review of In Vitro Studies.The International journal of prosthodontics · 2026
- Comparison of microhardness, surface roughness, retain-->Candida albicans adhesion, and color stability among TiO₂-coated and uncoated conventional, milled, and 3D printed denture base materials.The Journal of prosthetic dentistry · 2026
- Comparison of mechanical and optical properties of 3D printed denture bases.The Journal of prosthetic dentistry · 2026