Development and external validation of machine learning models for predicting glucose trajectories after continuous intravenous insulin therapy in hyperglycemic crises.
Yuichiro Iwamoto, Tomohiko Kimura, Yuichi Morimoto, Hideyuki Iwamoto, Yoshiro Fushimi, Junpei Sanada, Hayato Isobe, Fuminori Tatsumi,
Department of Diabetes, Endocrinology and Metabolism, Kawasaki Medical School, Kurashiki, Japan. · Department of Pediatrics, Kindai University Faculty of Medicine, Osakasayama, Japan.
Key points
From the paper's conclusion- The direct retest glucose model showed stable performance across internal and external validation, whereas ΔGlu itself was more difficult to generalize across institutions. These complementary models may support objective monitoring of short-term glucose trajectories during CII for hyperglycemic crises, although further prospective validation is warranted.
Abstract
BACKGROUND AND AIMS: Predicting short-term blood glucose changes after initiation of continuous intravenous insulin infusion (CII) in hyperglycemic crises remains challenging because glucose trajectories are influenced by both patient-specific metabolic severity and dynamically adjusted treatment. This study aimed to develop and externally validate machine learning models for estimating retest glucose levels and glucose-lowering responses after CII initiation. METHODS: We analyzed 574 post-CII blood glucose measurements from 191 patients with hyperglycemic crises across five Japanese institutions. An independent external validation cohort included 29 patients from another institution. Two complementary models were developed using gradient-boosted decision tree algorithms: a direct retest glucose prediction model and a ΔGlu treatment-response model. We evaluated model performance using internal validation, patient-level fivefold cross-validation, and external validation. ΔGlu was defined as the decrease in blood glucose between two consecutive reassessment points. RESULTS: The eight-feature direct retest glucose model showed stable predictive performance in internal validation (R2 = 0.853, MAE = 76.9 mg/dL, RMSE = 106.0 mg/dL), patient-level fivefold cross-validation (R2 = 0.803 ± 0.080), and external validation (R2 = 0.802, MAE = 78.0 mg/dL, RMSE = 101.0 mg/dL). Although the eight-feature ΔGlu treatment-response model showed moderate internal performance, its external generalizability for ΔGlu prediction was limited. CONCLUSIONS: The direct retest glucose model showed stable performance across internal and external validation, whereas ΔGlu itself was more difficult to generalize across institutions. These complementary models may support objective monitoring of short-term glucose trajectories during CII for hyperglycemic crises, although further prospective validation is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine learning glucose forecasting models for septic patientsScientific Reports · 2025
- Early ICU glycemic trajectory phenotypes predict short- and long-term mortality in critically ill patients: a dual-database cohort studyMetabolism Open · 2026
- Predictive Modelling of 3-Month Glycemic Target Achievement in Type 2 Diabetes Mellitus Using Artificial Intelligence and Continuous Glucose Monitoring: A Retrospective Cohort Study.Diabetes, obesity & metabolism · 2026
- Rapid identification of severe hypoglycemia and hyperglycemia in hospitalized patients using laboratory-integrated machine learning.Internal and emergency medicine · 2026
- Machine Learning Models for Glycemic Prediction in Type 1 and Type 2 Diabetes: Systematic Review and Meta-Analysis.Journal of medical Internet research · 2026
- Early, unplanned readmission in diabetes inpatients: Comparing the utility and performance of machine learning and traditional prediction models to guide timely diabetes management team reviewDiabetic Medicine · 2025