Clinical Outcomes Following Non-Surgical Periodontal Therapy of Intrabony Defects With Narrow or Wide Radiographic Angle. A Short-Term Retrospective Analysis.
Iorio-Siciliano Vincenzo, Blasi Andrea, Cuozzo Alessandro, Marini Lorenzo, Nibali Luigi, Ramaglia Luca
Periodontology Unit, Department of Neuroscience, Reproductive Sciences and Dentistry, University of Naples Federico II, Naples, Italy. · Section of Periodontics, Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy.
Key points
From the paper's conclusion- Aim To evaluate the clinical outcomes of non‐surgical periodontal therapy (NSPT) in intrabony defects with narrow (< 37°) or wide (≥ 37°) radiographic defect angle (RDA).
Abstract
AIM: To evaluate the clinical outcomes of non-surgical periodontal therapy (NSPT) in intrabony defects with narrow (< 37°) or wide (≥ 37°) radiographic defect angle (RDA). MATERIAL AND METHODS: Forty-nine patients with 135 defects (61 with RDA < 37° and 74 with RDA ≥ 37°) were screened from the Biobank of King's College London. Probing depth (PD), clinical attachment level (CAL), gingival recession (GR) and bleeding on probing (BOP) were assessed at baseline and after 3 months. The percentage of pocket closure was also evaluated. Additional subgroup analysis between narrow and wide defects with shallow (≤ 4 mm) or deep (> 4 mm) intrabony component was performed. The primary outcome was PD change. RESULTS: Clinical parameters significantly improved after 3 months (p < 0.05); however, no statistically significant changes (p > 0.05) were found between narrow and wide defects. At 3 months, the mean change of PD was 1.7 ± 2.2 and 2.0 ± 2.2 mm for the narrow and wide defects, respectively. The proportion of pocket closure was 27% and 37.7% for narrow and wide defects, respectively. No statistically significant difference (p > 0.05) was noted. Multilevel regression analysis showed that PD was a negative predictor (OR = 0.675) of pocket closure. CONCLUSIONS: Within the study limitations, these results indicate that NSPT improves clinical outcomes of narrow and wide defects. Baseline RDA did not affect the outcomes of NSPT. Short follow-up and the absence of wide/deep defects represent the major limitation, so the results cannot be generalised to all intrabony defects.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A 2-Year Prospective Observational Study of 2.9-mm Narrow-Diameter Implants for Single Maxillary Lateral Incisors.Healthcare (Basel, Switzerland) · 2026
- Peri-Implant Radiographic Measurements Compared With Intra-Surgical Assessments: Diagnostic Accuracy and Reproducibility.Journal of periodontal research · 2026
- Non‐incised papillae surgical approach for intrabony defects utilizing advanced platelet‐rich fibrin/xenograft compositeClinical Advances in Periodontics · 2026
- Three-Year Apical Outcomes in Teeth with Apical Periodontitis Following Primary Endodontic Treatment or Nonsurgical Retreatment: A Retrospective Clinical Study.Journal of clinical medicine · 2026
- Comparative Clinical Outcomes of Laser-Assisted Periodontal Therapy Versus Conventional Scaling and Root Planing in Patients With Chronic Periodontitis: A Prospective Nonrandomized Study.Cureus · 2026
- Polymerized injectable platelet-rich fibrin with octacalcium phosphate (bontree®) for treatment of periodontal intrabony defects assessed using CBCT: A randomized controlled clinical trial.Bioinformation · 2026