Safety and Efficacy of Linear Ablation for Peri-Mitral Annular Atrial Flutter Using the Pentaspline Pulse Field Ablation Catheter.
Connor P Oates, Scott Grubman, William Whang, Mohit K Turagam, Daniel Musikantow, Joshua Lampert, Marc A Miller, Jacob S Koruth,
Mount Sinai Fuster Heart Hospital, Icahn School of Medicine at Mount Sinai, New York, New York, USA. · Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Key points
From the paper's conclusion- While the pentaspline catheter can achieve acute procedural success when treating peri-mitral AFL with linear ablation of the mitral annulus, the long-term efficacy of this treatment strategy is modest.
Abstract
BACKGROUND: Despite widespread use of the pentaspline pulse field ablation (PFA) catheter to treat atrial fibrillation, there is limited data supporting its feasibility, safety, and effectiveness in creating linear lesions to treat peri-mitral atrial flutter (AFL). OBJECTIVE: To assess the safety and efficacy of using the pentaspline PFA catheter to treat peri-mitral AFL. METHODS: We performed a single-center retrospective review of consecutive patients receiving catheter ablation using the pentaspline PFA catheter to treat peri-mitral macroreentrant AFL. RESULTS: A total of 80 patients underwent catheter ablation for clinical peri-mitral AFL. Ablation was guided by electroanatomic mapping in all patients. AFL was treated with a lateral mitral line in 38 patients (47.5%), an anteroseptal mitral line in 31 patients (38.8%), a septal mitral line in 6 patients (7.5%), and an anterolateral mitral line in 5 patients (6.3%). Acute procedural success was achieved in 70 patients (87.5%) using the pentaspline catheter; the remaining 10 patients (12.5%) required additional radiofrequency ablation to achieve procedural success. Acute complications occurred in 4 (5.0%) patients: 2 (2.5%) patients sustained electrical isolation of the left atrial appendage, 1 (1.3%) had transient hematuria, and 1 (1.3%) had pericarditis. After a median follow-up of 322 days (IQR 192-432), 42 patients (52.5%) had recurrent AFL. Of these patients, 26 patients underwent a repeat ablation procedure-all demonstrated electrical breakthrough across the prior mitral line. CONCLUSIONS: While the pentaspline catheter can achieve acute procedural success when treating peri-mitral AFL with linear ablation of the mitral annulus, the long-term efficacy of this treatment strategy is modest.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Lesion Durability of the Second Generation Pentaspline Pulsed Field Ablation Catheter NAVIGATE-PF Phase 2 ResultsCirculation Arrhythmia and Electrophysiology · 2026
- Pulsed Field Ablation with the Pentaspline Catheter vs Radiofrequency Ablation for Recurrent Atrial Fibrillation.CJC open · 2026
- Early clinical experience with single-catheter map-and-ablate pentaspline PFA workflows in Europe: findings from the OPALISE Sub-Study of the FARAVERSE RegistryEuropean Heart Journal · 2026
- Pulsed electric field for pulmonary vein isolation in paroxysmal atrial fibrillation: A multicenter experience comparing pentaspline and lattice-tip catheters.Heart rhythm O2 · 2026
- Safety and Efficacy of Pulsed-Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.Clinical cardiology · 2026
- Is it possible to ablate typical atrial flutter using pulsed field energy quickly, effectively and safely? Real-world experience with the CENTAURI PEF systemEuropean Heart Journal · 2026