Outcomes of a co-designed clinical decision support tool for inpatient glycaemia management.
Megan Dharma, Rahul D Barmanray, Andrew Coote, Samantha Plumb, Mervyn Kyi, Spiros Fourlanos, Timothy N Fazio
Department of Diabetes and Endocrinology, The Royal Melbourne Hospital, Melbourne, Victoria, Australia. · Electronic Medical Record Team, The Royal Melbourne Hospital, Melbourne, Victoria, Australia.
Key points
From the paper's conclusion- Despite multidisciplinary co-design, education and implementation, non-interruptive alerts for glycaemia were not electronically acknowledged in most cases. The alert did not change medication management and thus was unlikely to be the cause of reduction in recurrence of adverse glycaemic events. Further research is required to determine barriers, to develop strategies to improve user engagement and to optimise glycaemic-based electronic alerts, aiming to assist health professionals working in acute care.
Abstract
BACKGROUND: Hypo- and hyperglycaemia are major issues for hospital inpatients with diabetes, associated with risk of increased adverse outcomes, including higher mortality and prolonged length of stay. AIMS: We investigated whether implementation of a multidisciplinary co-designed, non-interruptive electronic medical record (EMR)-based alert for glycaemia was associated with changes in diabetes medication management in hospital. METHODS: This was an observational study from September 2022 to January 2023 comparing 7-week pre-intervention and intervention periods separated by a 4-week non-analysis transition. Non-interruptive alerts for hypo- and hyperglycaemia were deployed through the EMR, which provided management recommendations. The primary outcome was electronic alert acknowledgement. Secondary outcomes included medication changes and adverse glycaemic event recurrence. RESULTS: During the intervention period, rates of alert acknowledgement were very low (hypoglycaemia 1.0% and hyperglycaemia 0.1%). Following alert implementation there was no significant change in medication modification in response to hypoglycaemia (relative risk (RR) 1.42, P = 0.500) or hyperglycaemia (RR 0.64, P = 0.141) events compared with pre-intervention. There was no significant difference in risk for hypoglycaemia recurrence (RR 1.89, P = 0.443), but the risk for hyperglycaemia recurrence was lower (RR 0.79, P = 0.014) during intervention compared to pre-intervention. CONCLUSION: Despite multidisciplinary co-design, education and implementation, non-interruptive alerts for glycaemia were not electronically acknowledged in most cases. The alert did not change medication management and thus was unlikely to be the cause of reduction in recurrence of adverse glycaemic events. Further research is required to determine barriers, to develop strategies to improve user engagement and to optimise glycaemic-based electronic alerts, aiming to assist health professionals working in acute care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Threshold and Predictive Alerts of Continuous Glucose Monitoring and Glycemic Control in Hospitalized Adults With Diabetes: A Randomized Clinical Trial.JAMA network open · 2026
- Automated, Component-Level Assessment of a National Inpatient Diabetes Guideline: Adherence and Its Association with Hospitalization Complications Across Six HospitalsmedRxiv · 2026
- Continuous Glucose Monitoring Hypoglycemia Alarms in Critical Care: Clinical Utility and Workflow Integration.Diabetes technology & therapeutics · 2026
- Assessment of Hypoglycemia Management in Acute Care Hospitals.HCA healthcare journal of medicine · 2026
- Evaluation of Diabetic Ketoacidosis Outcomes Following the Adoption of a Computer-Based Variable-Rate Insulin Infusion Algorithm.Journal of diabetes science and technology · 2026
- Transforming Inpatient Glycemic Management: A System-Wide Approach to Reducing Hyperglycemia and Hypoglycemia.Diabetes, obesity, and cardiometabolic CARE · 2026