International journal of dental hygiene

Do Oral Hygiene Methods Alter Titanium Implant Surfaces? An In Vitro Surface Roughness Analysis.

Vaishnavi Pandey, Rupali Agnihotri

Department of Periodontology, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India.

Preclinical · n=12

Key points

From the paper's conclusion
  • Exposure to therapeutic oral hygiene protocols (Regimens A and B) significantly elevated Ti6Al4V roughness, while isolated bristle friction (Regimen C) had a negligible impact. Pre-textured sandblasted surfaces exhibited greater vulnerability to structural wear than polished surfaces, highlighting the need for surface-specific, individualized implant hygiene protocols.

Abstract

OBJECTIVES: This study evaluated and compared the effects of three simulated daily oral hygiene regimens on the surface roughness (Ra) of titanium alloy (Ti6Al4V) discs. METHODS: Twenty-four Ti6Al4V discs were allocated to two groups based on baseline surface characteristics (n = 12/group): Group 1 (Polished) and Group 2 (Sandblasted). Each was subdivided into three 30-day regimens (n = 4/regimen): Regimen A (Chemical only: 0.2% chlorhexidine digluconate (CHX) mouthrinse immersion), Regimen B (Combined electric toothbrushing [ETb] + fluoridated toothpaste [TP] + CHX after a 30-min washout), and Regimen C (mechanical control: ETb + distilled water). Atomic force microscopy (AFM) quantified Ra values at baseline and at 30 days. Data were evaluated using three-way mixed ANOVA, one-way ANOVA, and post hoc Bonferroni corrections (p < 0.05). RESULTS: Three-way mixed ANOVA revealed a significant interaction among time, surface type, and regimen (F (2, 18) = 30.58, p < 0.001). Post hoc tests showed that Regimens A and B significantly increased Ra values in Group 1 (A: p = 0.0001; B: p = 0.001) and in Group 2 (A: p = 0.005; B: p = 0.0008). Conversely, Regimen C produced no significant alterations (p > 0.05). Baseline one-way ANOVA confirmed that Group 2 possessed significantly higher Ra values than Group 1 (p < 0.001). CONCLUSION: Exposure to therapeutic oral hygiene protocols (Regimens A and B) significantly elevated Ti6Al4V roughness, while isolated bristle friction (Regimen C) had a negligible impact. Pre-textured sandblasted surfaces exhibited greater vulnerability to structural wear than polished surfaces, highlighting the need for surface-specific, individualized implant hygiene protocols.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Do Oral Hygiene Methods Alter Titanium Implant Surfaces? An In Vitro Surface Roughness Analysis — Science Skim