Non-Invasive Intracranial Pressure Waveform Assessment as a Screening Test for Abnormal Lumbar Puncture Results.
Gabriel Taricani Kubota, Alessandra Santos da Fonseca, Cintya Yukie Hayashi, Rebecca Gabriela de Oliveira Pereira, Thauan Gonçalves, Helio Rodrigues Gomes, Valquíria Aparecida da Silva, Ida Fortini,
Department of Neurology, University of Sao Paulo, Sao Paulo, Brazil. · Brain4Care Brazil, São Carlos, Brazil.
Key points
From the paper's conclusion- NIWA was feasible and detected IH and CSF changes with high sensitivity among real-world neurological outpatients. While LP remains pivotal to many cases, pre-LP screening with NIWA may enhance diagnostic yield and mitigate complications and healthcare-related costs.
Abstract
BACKGROUND: Lumbar puncture (LP) is essential for detecting intracranial hypertension (IH) but is often non-diagnostic and not without complications. A skull extensometer-based non-invasive intracranial pressure waveform assessment (NIWA) has shown promise in detecting IH in neurocritical settings. This study investigated its feasibility and accuracy among outpatient neurological individuals. METHODS: This cross-sectional study enrolled adults referred to routine outpatient LP at a tertiary-care hospital. Subjects underwent baseline supine NIWA, then were sequentially divided (2:1:1 ratio) to: LP then follow-up supine NIWA; follow-up NIWA while sitting then LP; or follow-up NIWA during Valsalva maneuver then LP. Several waveform parameters and their variation between baseline and follow-up assessments were compared with LP results. IH was defined as LP opening pressure > 25cmH2O. RESULTS: The study included 130 subjects, and 28 (21.5%) presented with IH. Dicrotic peak slope < 0.143 predicted IH with 89.5% sensitivity and 29.7% specificity (AUROC = 0.680, 95% CI 0.541-0.819). Equations derived from multivariate logistic regression models including mostly latency-related parameters of the entire waveform and its percussion and dicrotic peaks predicted cerebrospinal fluid (CSF) chemocytology changes with AUROC = 0.661 (95% CI 0.542-0.780) and overall abnormal LP results (IH and/or altered CSF chemocytology) with 96.2% sensitivity and 24.1% specificity (AUROC = 0.696, 95% CI 0.572-0.820). Parameter changes after LP, during Valsalva maneuver, and sitting position did not improve diagnostic accuracy. CONCLUSIONS: NIWA was feasible and detected IH and CSF changes with high sensitivity among real-world neurological outpatients. While LP remains pivotal to many cases, pre-LP screening with NIWA may enhance diagnostic yield and mitigate complications and healthcare-related costs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of Intracranial Hypertension With Noninvasive Subharmonic-Aided Pressure Estimation: A First-in-Humans Trial.Ultrasound in medicine & biology · 2026
- The use of a non-invasive neuromonitoring device in the emergency department: comparison with computed tomography results.Journal of clinical monitoring and computing · 2026
- Correlation of Perfusion Index and Inferior Vena Cava Collapsibility Index in Preoperative Patients: A Prospective Analytical Study.Cureus · 2026
- Noninvasive Intracranial Pressure Estimation Using Subspace System Identification and Machine Learning Algorithms: A Learning-to-Rank Approach.IEEE transactions on bio-medical engineering · 2026
- Intracranial Pressure Estimation Using B4C Device: A Systematic Review on the Validation Studies.Neurocritical care · 2026
- Evolution of the Criteria to Diagnose Idiopathic Intracranial Hypertension: An Algorithm.Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society · 2026