Echocardiography (Mount Kisco, N.Y.)

Determining the Optimal Left Ventricular Outflow Tract Assessment for Aortic Valve Area Calculation in Tricuspid and Bicuspid Valves Using 3D Echocardiography.

Alex Frampton, Adrian Chong, Mark Dooris, Sudhir Wahi, William Y S Wang

Princess Alexandra Hospital, Brisbane, Australia. · Mater Hospital Brisbane, Brisbane, Australia.

Key points

From the paper's conclusion
  • 3D TTE provides optimal assessments of the LVOT for AVACE calculations. 3D-based LVOTAs are suitable for both TAVs and BAVs. If 3D is unavailable, 2D LVOTD measurements should be performed at the annulus.

Abstract

PURPOSE: The weakest link in aortic valve area (AVA) calculation by the continuity equation (AVACE) during 2D transthoracic echocardiography (TTE) is underestimation of the left ventricular outflow tract (LVOT) diameter (LVOTD). Proposed solutions were founded on 2D imaging, geometrical assumptions, and validated exclusively in tricuspid aortic valves (TAV). There is little evidence to guide imaging optimization in bicuspid valves (BAV) despite recognized differences in their LVOT morphologies. We aimed to determine the optimal approach for LVOT assessment in TAVs and BAVs using 3D TTE. METHODS: Patients with 2D and 3D TTE assessments of the LVOT and aortic valve were identified. LVOTDs were measured on 2D images while multiplanar reconstructions of the 3D datasets were performed to obtain LVOT area (LVOTA) and circumference (LVOTC). AVACE was calculated using the different 2D/3D LVOT measurements and compared with AVA by 3D planimetry (AVA3D). RESULTS: 100 TAVs (mean age 46.2 ± 17.5years, 36% females) and 100 BAVs (34.9 ± 14.5years, 50% females) were included. In comparison to AVA3D, calculation of AVACE in TAVs was best using 3D LVOTA (Intraclass correlation coefficient (ICC)>0.9; P < 0.001), while LVOTC resulted in overestimation of the AVA due to greater LVOT ellipticity. In BAVs, both 3D LVOTA and LVOTC resulted in ICCs>0.9 (P < 0.001). 2D LVOTDs resulted in underestimation of the AVA with a smaller error if measured at the annulus. CONCLUSIONS: 3D TTE provides optimal assessments of the LVOT for AVACE calculations. 3D-based LVOTAs are suitable for both TAVs and BAVs. If 3D is unavailable, 2D LVOTD measurements should be performed at the annulus.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Determining the Optimal Left Ventricular Outflow Tract Assessment for Aortic Valve Area Calculation in Tricuspid and Bicuspid Valves Using 3D Echocardiography — Science Skim