Echocardiography (Mount Kisco, N.Y.)

Study on Wall Shear Stress Changes in the Aortic Arch and Isthmus in Fetuses With Aortic Coarctation Using Vector Flow Mapping.

Zhe Xu, Shi Zeng, Xueyi Tong, Abdoul Rachid Aboubacar Hamidou, Yushan Liu, Bo Liu

Department of Ultrasound Diagnosis, The Second Xiangya Hospital of Central South University, Changsha, Hunan, China.

Observational

Key points

From the paper's conclusion
  • Isthmus WSSmax is elevated in fetuses with CoA and is independently associated with greater isthmus hypoplasia and higher isthmus flow velocity, suggesting a role in CoA pathophysiology. Its incremental diagnostic value could not be assessed because the control group consisted of normal fetuses. WHAT IS ALREADY KNOWN ABOUT THIS TOPIC?: Prenatal diagnosis of aortic coarctation (CoA) has a high false‑positive rate. Hemodynamic changes in CoA include increased velocity and turbulence, but biomechanical assessment in fetuses is limited. WHAT DOES THIS STUDY ADD?: This study uses VFM to quantify WSSmax in the fetal aortic arch and isthmus. Isthmus WSSmax is significantly elevated in fetuses with CoA and is independently associated with greater isthmus hypoplasia and higher isthmus flow velocity, providing mechanistic insights into the biomechanical alterations of fetal CoA.

Abstract

OBJECTIVE: To evaluate segmental peak systolic wall shear stress (WSSmax) in the aortic arch and isthmus of fetuses with coarctation of the aorta (CoA) and to explore its relationships with conventional anatomical and hemodynamic parameters. METHODS: This prospective study included 58 CoA fetuses and 58 gestational age-matched normal controls. Vector flow mapping measured WSSmax at the inner and outer curvatures of the aortic arch and isthmus. Within the CoA group, Spearman correlation was used to assess relationships between isthmus WSSmax and the isthmus Z-score, PA/AO, TV/MV, isthmus Vmax, and RV/LV. Multivariable linear regression was performed using the isthmus Z-deficit (-Z), PA/AO, and isthmus Vmax. RESULTS: Arch WSSmax did not differ between groups (all p > 0.05). Isthmus WSSmax (general, inner, and outer curvature) was significantly higher in the CoA group than in controls (all p < 0.05). Within the CoA group, isthmus WSSmax was lower than arch WSSmax (all p < 0.05). Isthmus WSSmax was correlated with the isthmus Z-score, PA/AO, and isthmus Vmax. In multivariable regression, isthmus Z-deficit (B = 0.271, 95% CI 0.031-0.510, p < 0.05) and isthmus Vmax (B = 0.01, 95% CI 0.001-0.020, p < 0.05) were independently associated with isthmus WSSmax, whereas PA/AO was not significant (p > 0.05). CONCLUSION: Isthmus WSSmax is elevated in fetuses with CoA and is independently associated with greater isthmus hypoplasia and higher isthmus flow velocity, suggesting a role in CoA pathophysiology. Its incremental diagnostic value could not be assessed because the control group consisted of normal fetuses. WHAT IS ALREADY KNOWN ABOUT THIS TOPIC?: Prenatal diagnosis of aortic coarctation (CoA) has a high false‑positive rate. Hemodynamic changes in CoA include increased velocity and turbulence, but biomechanical assessment in fetuses is limited. WHAT DOES THIS STUDY ADD?: This study uses VFM to quantify WSSmax in the fetal aortic arch and isthmus. Isthmus WSSmax is significantly elevated in fetuses with CoA and is independently associated with greater isthmus hypoplasia and higher isthmus flow velocity, providing mechanistic insights into the biomechanical alterations of fetal CoA.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts