Effect of a Computer-Aided Device on Endoscopists' Biopsy Practice for Gastric Neoplasms: A Secondary Analysis of a Randomized Controlled Trial.
Hongliu Du, Shuzhe Tan, Ziyi Zeng, Xinran Zhang, Zehua Dong, Mei Deng, Jiamin Wang, Xiao Tao,
Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China.
Key points
From the paper's conclusion- Methods This study is a secondary analysis of a randomized controlled trial (AI group: n = 13,440; control: n = 12,561) compared AI‐assisted versus standard screening.
Abstract
BACKGROUND: Endoscopic biopsy is fundamental for diagnosing gastrointestinal lesions, yet the effectiveness of AI assistance on endoscopists' biopsy strategies and efficiency for detecting gastric neoplasms remains unclear. This study aims to investigate this effectiveness. METHODS: This study is a secondary analysis of a randomized controlled trial (AI group: n = 13,440; control: n = 12,561) compared AI-assisted versus standard screening. The AI system marked high-risk and low-risk lesions with red and blue boxes, respectively. The AI group was stratified into red-box and non-red-box subgroups. Outcomes included neoplasm biopsy efficiency and proportion of non-biopsied documented lesions. The patient-level correlation between false-positive alerts and biopsy counts was examined. All analyses were based on the pathological results after centralized pathology review. RESULTS: The non-biopsy rate was significantly lower in the red-box group than in the non-red box group and the control group (18.00% vs. 43.26%, 18.00% vs. 45.60%, both p < 0.001), suggesting that lesions were biopsied more frequently in the red-box group. Neoplasm biopsy efficiency was higher in the red-box group (8.19% vs. 0.36%, 8.19% vs. 1.77%, both p < 0.001). In negative binomial regression, red-box classification remained associated with a lower non-biopsy rate (IRR 0.393, 95% CI 0.360-0.429, p < 0.001). False-positive alerts showed a weak inverse correlation with biopsy counts (ρ = -0.182, p < 0.001). CONCLUSIONS: Red-box classification was associated with more targeted biopsy sampling, while false-positive prompts were not associated with indiscriminate biopsies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of a Computer-Aided Device for Detecting Gastric Neoplasms: A Multicenter, Randomized Controlled TrialGastroenterology · 2026
- Impact of Artificial Intelligence‐Assisted Endoscopy on Screening for Upper Gastrointestinal Cancer in a Large‐Scale Health Screening FacilityDigestive Endoscopy · 2026
- Artificial Intelligence-Based Triage and Diagnostic Support for Gastric Biopsies: A Multi-Centre Prospective Evaluation Across NHS Wales.Diagnostics (Basel, Switzerland) · 2026
- Impact of AI-Assisted Endoscopy on Secondary Review and Referral Decisions in Gastric Cancer Screening: A Multicenter Real-World Study.Journal of gastroenterology and hepatology · 2026
- A multi-class gastric biopsy artificial intelligence model developed from whole slide histopathological images.NPJ digital medicine · 2026
- The Impact of Artificial Intelligence-Assisted Endoscopy on the Detection of Upper Gastrointestinal Neoplasms: A Systematic Review and Meta-Analyses.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026