科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society2026-09-01

Development and Crossover Evaluation of an Artificial Intelligence-Assisted System for Solid Pancreatic Lesion Detection and Pancreatic Parenchyma Recognition in Endoscopic Ultrasonography (With Video).

Toshio Fujisawa, Takamichi Kuwahara, Tatsuya Sato, Yusuke Takasaki, Nozomi Okuno, Ryunosuke Hakuta, Ko Tomishima, Shin Haba, Naminatsu Takahara, Yukiko Ito, Yousuke Nakai, Kazuo Hara, Hiroyuki Isayama

一句话结论 · In one sentence

AI assistance improved SPL detection among novice endosonographers. For PP recognition, sensitivity increased without reaching statistical superiority, whereas specificity met the predefined noninferiority criterion. These findings support a potential adjunctive role for AI in EUS interpretation.

原始摘要(英文原文)· Original abstract
BACKGROUND AND STUDY AIMS: Pancreatobiliary endoscopic ultrasonography (EUS) is technically demanding, and supervised training opportunities are limited. We developed an artificial intelligence (AI) overlay system for detecting solid pancreatic lesions (SPL) and recognizing pancreatic parenchyma (PP) and evaluated its effect on reader performance. PATIENTS AND METHODS: Across six centers, two deep learning-based models were trained using expert-annotated EUS frames. We then conducted a randomized, two-sequence, two-period crossover reader study in which eight endosonographers (five novices and three experts) interpreted image sets with and without AI assistance. The primary endpoint was superiority of sensitivity for SPL detection among novices; key secondary endpoints included specificity and PP recognition. RESULTS: From 118 patients, 120 SPL-positive/negative image sets and 160 PP-positive/negative image sets were constructed. Among novices, AI assistance improved SPL detection sensitivity (88.7% vs. 76.8%, p < 0.001) and accuracy (86.4% vs. 78.7%), while specificity met the predefined noninferiority criterion (84.2% vs. 80.5%, p < 0.001). For PP recognition, sensitivity increased numerically (86.3% vs. 83.3%) but did not meet the predefined superiority criterion (p = 0.095); specificity met the noninferiority criterion (87.8% vs. 81.0%), and accuracy increased from 82.1% to 87.0%. Among experts, sensitivity was maintained for both tasks, whereas specificity increased with AI assistance. CONCLUSIONS: AI assistance improved SPL detection among novice endosonographers. For PP recognition, sensitivity increased without reaching statistical superiority, whereas specificity met the predefined noninferiority criterion. These findings support a potential adjunctive role for AI in EUS interpretation.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Development and Crossover Evaluation of an Artificial Intelligence-Assisted System for Solid Pancreatic Lesion Detection and Pancreatic Parenchyma Recognition in Endoscopic Ultrasonography (With Video). — 科研速览 Science Skim