Morphology-Based Cytosponge Cytology Versus Concurrent Endoscopic Biopsy for Detecting Dysplasia in Barrett's Oesophagus Surveillance: A Prospective, Single-Centre Paired Study.
Vincent Labador, Cherry Galorport, Hamid Masoudi, Robert Enns, Eric Lam, Neal Shahidi, Pam Wong, Wei Xiong
Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada. · Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.
Key points
From the paper's conclusion- Cytosponge cytology showed high specificity and moderate sensitivity for dysplasia, with a positive result strongly predicting biopsy-confirmed dysplasia. These pilot data support further evaluation of Cytosponge cytology, reported by trained pathologists, as a non-endoscopic triage tool in BE surveillance.
Abstract
BACKGROUND: Barrett's oesophagus (BE) is the principal precursor of oesophageal adenocarcinoma, and guidelines recommend endoscopic surveillance to detect dysplasia. Endoscopy is invasive and resource-intensive. The Cytosponge is a non-endoscopic cell-collection device. We evaluated Cytosponge cytology against concurrent endoscopic biopsy for detecting dysplasia in a BE surveillance population, and explored factors associated with sample adequacy. METHODS: In this prospective, single-centre study, patients with established BE underwent a Cytosponge procedure with a concurrent same-visit endoscopic biopsy. Cytosponge cell blocks were stained with H&E and Alcian Blue 2.5/Periodic Acid-Schiff. Two blinded gastrointestinal pathologists recorded goblet cells and dysplasia by consensus. Sensitivity, specificity, and predictive values with 95% confidence intervals (CI) were calculated against biopsy, and age-adequacy association tested with Fisher's exact test. RESULTS: Fifty-nine participants were analyzed (median age 70 years; 93.2% male). Cytosponge samples were adequate in 46/59 (78.0%; 95% CI 65.9-86.6). Among 44 adequate paired samples, sensitivity for dysplasia was 76.5% (95% CI 52.7-90.4), specificity 92.6% (76.6-97.9), positive predictive value 86.7%, and negative predictive value 86.2%. Sensitivity for definite (low- plus high-grade) dysplasia was 85.7% (12/14); the lower overall figure reflected indefinite-for-dysplasia cases, of which only one of three was detected. Inadequacy was higher in patients aged ≥ 71 than ≤ 70 years (30% vs. 16%; p = 0.22). No procedural complications occurred. CONCLUSIONS: Cytosponge cytology showed high specificity and moderate sensitivity for dysplasia, with a positive result strongly predicting biopsy-confirmed dysplasia. These pilot data support further evaluation of Cytosponge cytology, reported by trained pathologists, as a non-endoscopic triage tool in BE surveillance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Non-Endoscopic Screening for Barrett's Esophagus Using a DNA Methylation-Based Assay: Real-World Experience in 11,991 Patients.Diagnostics (Basel, Switzerland) · 2026
- Clinical Trial: Capsule Sponge as a Non-Endoscopic Monitoring Tool in Eosinophilic Oesophagitis-A Prospective Real-World Multicentre Study.Alimentary pharmacology & therapeutics · 2026
- Using a mobile unit to deliver capsule sponge testing for Barrett's oesophagus in the community in England through GP invitation and self-referral: an implementation study.BMJ open gastroenterology · 2026
- Prior endoscopic surveillance and diagnosis of Barrett-related dysplasia and cancer: evidence from a nationwide Dutch cohort.Gut · 2026
- Probe-based confocal laser endomicroscopy: progress, challenges, and emerging applicationsSurgical Endoscopy · 2025
- Diagnostic Accuracy of a Capsule Sponge Trefoil Factor 3 Test for Barrett's Esophagus in Patients with Gastroesophageal Reflux Disease: A Systematic Review and Meta-Analysis.The American journal of gastroenterology · 2026