The impact of defects of the atrial septum on procedural complexity, complications, and outcomes of transvenous lead extraction.
Dorota Nowosielecka, Wojciech Jacheć, Christoph Starck, Anna Polewczyk, Dominika Mościcka, Andrzej Kutarski
Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland. · 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Silesian Medical University in Katowice, Zabrze, Poland.
Key points
From the paper's conclusion- In this large TLE cohort, DAS was uncommon and associated with greater procedural complexity, but not with a higher incidence of major complications or worse long-term survival. Clinically apparent systemic embolic events were rare.
Abstract
BACKGROUND: Patients with defects of the atrial septum (DAS) undergoing transvenous lead extraction (TLE) may be at increased risk of systemic embolism due to transient right-to-left shunting. However, data on the prevalence and clinical relevance of DAS in patients undergoing TLE remain limited. METHODS: This retrospective study included 3637 patients undergoing TLE between 2006 and 2024 with complete preprocedural assessment of the atrial septum and at least 3 years of follow-up. We evaluated the prevalence of DAS and its association with procedural complexity, major complications, and survival. RESULTS: DAS was identified in 3.71% of patients. Patent foramen ovale was present in 2.45%, secundum atrial septal defect in 1.15%, and both defects in 0.08%. Most defects were small, with predominant left-to-right shunting. Patients with DAS more frequently had lead-related infective endocarditis and vegetations on transesophageal echocardiography (p < 0.001). TLE procedures in patients with DAS were more complex, with longer extraction times and more frequent use of advanced extraction tools. Despite higher predicted procedural risk, the incidence of major complications, including stroke, was low. DAS was not associated with increased in-hospital, 30-day, 1-year, or 3-year mortality. CONCLUSIONS: In this large TLE cohort, DAS was uncommon and associated with greater procedural complexity, but not with a higher incidence of major complications or worse long-term survival. Clinically apparent systemic embolic events were rare.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessing the role of transesophageal echocardiography in transvenous lead extraction: is it still essential?European Heart Journal · 2026
- Transvenous Lead Extraction Without Dedicated Surgical Back up in Low-Risk Patients.Heart rhythm · 2026
- Female sex as an independent predictor of major complications during transvenous lead extraction.Heart rhythm · 2026
- Safety and Efficacy of Right- Versus Left-Sided Transvenous Lead Extraction.Journal of cardiovascular electrophysiology · 2026
- Safety and Outcomes of Percutaneous Vegetation Aspiration During Transvenous Lead Extraction: A Multicenter Experience.Journal of cardiovascular electrophysiology · 2026
- Iatrogenic atrial septal defect following pulsed field ablation using left atrial ICEEuropean Heart Journal · 2026