Electrode-Modiolar Distance as a Determinant of Cochlear Implant Performance: A Systematic Review and Meta-Analysis.
Nidhin Das K, Vidhu Sharma, Siddharth Manoj, Amit Goyal
Department of Otorhinolaryngology, All India Institute of Medical Sciences, Bilaspur, India. · Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India.
Key points
From the paper's conclusion- Conclusion Electrode–modiolar proximity is a strong and consistent determinant of CI performance with a clear dose–response relationship, supporting its role as a clinically actionable imaging biomarker for optimizing electrode selection, surgical strategy and individualized programming.
Abstract
OBJECTIVE: To quantify the relationship between electrode-modiolar distance (EMD) and cochlear implant (CI) performance across speech/perceptual, electrophysiological and programming outcomes and to characterize the dose-response effect of EMD. METHODS: A systematic search of PubMed/MEDLINE, Embase, Scopus, Web of Science and Cochrane CENTRAL was conducted in accordance with PRISMA guidelines. Human studies reporting CT- or CBCT-derived EMD and CI outcomes were included. Effect sizes were transformed to odds ratios (ORs) and pooled using random-effects models. Subgroup, sensitivity and dose-response analyses were performed. Heterogeneity was assessed using I2, and publication bias was evaluated using funnel plots and Egger's test. RESULTS: Twenty-one studies comprising approximately 1181 implanted ears were included. Reduced EMD was associated with significantly higher odds of favourable CI outcomes (pooled OR = 2.16, 95% CI: 1.89-2.45; p < 0.001; I2 = 0%). Consistent effects were observed for speech/perceptual outcomes (OR = 2.23), electrophysiological measures (OR = 2.80 after sensitivity adjustment) and programming parameters (OR = 1.72). Dose-response modelling demonstrated a monotonic gradient, with each 1 mm increase in EMD associated with a 20%-30% reduction in the odds of favourable outcomes (OR per mm ≈0.72; p < 0.001). No significant publication bias was detected (Egger's p = 0.056). CONCLUSION: Electrode-modiolar proximity is a strong and consistent determinant of CI performance with a clear dose-response relationship, supporting its role as a clinically actionable imaging biomarker for optimizing electrode selection, surgical strategy and individualized programming. TRIAL REGISTRATION: PROSPERO: CRD420261380236.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Changes in Electrode Impedance and Cochlear Microphonic in Cochlear Implant Recipients in the First Year After Cochlear Implantation.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Establishing reliable neural health measures in adult cochlear implant users.Frontiers in neuroscience · 2026
- Methodological implications of the minimal clinically important difference in patient-reported outcome measures in the field of cochlear implant provision.HNO · 2026
- The Interphase Gap Effect in Cochlear Implant Users: Biological Basis, Parameter Selection, Analytical Methods, and Quantitative ScalesJournal of the Association for Research in Otolaryngology · 2026
- Association of AutoART eCAP thresholds with behavioral THR and MCL in pediatric cochlear implant users.Cochlear implants international · 2026
- Optimisation of and mechanisms behind neural distortion responses obtained with cochlear-implant stimulation by interleaved pulse trainsmedRxiv · 2026