Clinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery

da Vinci Single-Port Transoral Robotic Surgery in European Practice: Early Outcomes and Comparison With Transoral Laser Microsurgery.

Matthew E Ryan, Matthew Zammit, Kristijonas Milinis, Omar Ahmed, Rupali Sawant, Ava Gubbay, Somer Scott-Clarkson, Harishanker Jeyarajan,

Department of Head and Neck Surgery, Aintree University Hospital, Liverpool University Hospitals NHS Foundation Trust, Liverpool, UK. · School of Medicine, University of Liverpool, Liverpool, UK.

Computational

Key points

From the paper's conclusion
  • These findings support safe integration of SP‐TORS into transoral surgical practice and justify prospective evaluation.

Abstract

OBJECTIVES: To report early outcomes following implementation of a da Vinci Single-Port transoral robotic surgery (SP-TORS) programme in the United Kingdom. To provide contextual benchmarking, outcomes were compared with a historical institutional cohort treated using transoral laser microsurgery (TLM). DESIGN: Retrospective institutional series with comparison against a historical cohort using stabilised inverse-probability-of-treatment weighting. SETTING: High-volume UK Tertiary Head and Neck Centre. PARTICIPANTS: All patients undergoing SP-TORS between April 2024 and September 2025. Comparative analyses were limited to oncological resections and included 33 SP-TORS and 61 TLM cases. MAIN OUTCOME MEASURES: Feasibility, peri-operative safety, postoperative haemorrhage, return to theatre, mortality, length of stay, time to oral diet, margin status and adjuvant therapy use. RESULTS: Sixty-six patients underwent SP-TORS. All procedures were completed transorally without unplanned conversion or peri-operative mortality. Postoperative haemorrhage occurred in 4.5%, with one return to theatre. Length of stay did not differ between groups. Time to oral diet was longer following SP-TORS (adjusted ratio 1.51, p= 0.005). ASCO-defined involved margins were similar (OR 0.30, 95% CI 0.06-1.56; p = 0.15), whereas specimen ink-positive margins were less frequent following SP-TORS (OR 0.31, 95% CI 0.11-0.91; p = 0.03). A sensitivity analysis using propensity-matched T1/T2 pairs demonstrated a consistent directional effect, though this did not reach significance in the smaller matched cohort. Adjuvant therapy use was comparable. CONCLUSION: SP-TORS implementation in a high-volume UK centre was feasible and safe during early adoption, with low complication rates. Peri-operative and early functional outcomes were broadly comparable with TLM. Although specimen ink-positive margins were less frequent following SP-TORS, interpretation should be cautious given the historical comparator and associated differences in departmental workflow. These findings support safe integration of SP-TORS into transoral surgical practice and justify prospective evaluation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

da Vinci Single-Port Transoral Robotic Surgery in European Practice: Early Outcomes and Comparison With Transoral Laser Microsurgery — Science Skim